My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Persons responsible for any facility where Class I materials are present shall comply with <br />all of the requirements of this subsection (b) and with subsection (c), (d), (e) and (f) of <br />this section. <br /> <br />(1) Piping <br /> <br />[i] Piping for Class I materials shall be designed and fabricated from materials <br />compatible with the material to be contained. Piping shall be of strength and durability <br />sufficient to withstand the pressure, structural and seismic stress and exposure to which it <br />may be subjected, as required by the Uniform Building Code of the Pleasanton Municipal <br />Code. <br /> <br />[ii] Secondary containment shall be provided for piping for Class I materials. The <br />secondary containment shall be capable of directing a sudden release into an approved <br />discharge treatment system, and shall be monitored continually with a continuous gas <br />monitoring system approved by the Fire Chief. Secondary containment, includes, but is <br />not limited to, double walled piping. <br /> <br />(2) Automatic Shut-Off. An automatic shut-offvalve which is of a "fail-safe to close" <br />design shall be provided. Each of the following shall activate automatic shut-off: <br /> <br />[i] Gas detection. <br /> <br />[ii] Manually, from remote locations. <br /> <br />[iii] Failure of emergency power. <br /> <br />[iv] Seismic activity, upon a seismic event within 5 seconds of horizontal semisoidal <br />oscillation having a peak acceleration of. 15g (--1.47m/sec2) and a period of .4 seconds. <br /> <br />[v] Failure of primary containment. <br /> <br />[vi] Activation of manual fire alarm. <br /> <br />[vii] Activation of an automatic fire suppression system. <br /> <br />(3) Emergency Control Station. Signals from emergency equipment shall be <br />transmitted to an emergency control station onsite, and transmitted to an Underwriters <br />Laboratory (UL) Central Station Service as directed by the Fire Chief. <br /> <br />(c) Class II Controls. <br /> <br />119 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.