My WebLink
|
Help
|
About
|
Sign Out
06 ATTACHMENTS
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2010
>
120710
>
06 ATTACHMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2010 2:01:19 PM
Creation date
12/1/2010 2:01:09 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
12/7/2010
DESTRUCT DATE
15Y
DOCUMENT NO
06 ATTACHMENTS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building and Safety Official, the interim, temporary or acting Building and Safety <br /> Official. <br /> 20.10.020 CRC Chapter 1 Division II is deleted. <br /> Chapter 1 Division II is deleted. <br /> 20.10.030 CRC Section R202 amended — Definitions <br /> Section R202 is amended by adding the following definition to read as follows: <br /> BALCONY, EXTERIOR, is an exterior floor projecting from and supported by a <br /> structure, without additional independent supports. <br /> 20.10.040 CRC Table R301.2(1) amended — Climate and Geographic Design <br /> Criteria <br /> Table R301.2(1) is amended to read as follows: <br /> TABLE R301.2(1) <br /> CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br /> SUBJECT TO DAMAGE ICE <br /> WIND DESIGN FROM BARRIER <br /> GROUND SEISMIC Frost WINTER UNDER- AIR MEAN <br /> SNOW Speed Topographic DESIGN line DESIGN LAYMENT FLOOD FREEZING ANNUAL <br /> LOAD (mph) effects" CATEGORY` Weathering' depth Termite` TEMP` REQUIRED" HAZARDS INDEX' TEMP <br /> 85 Do, Dl, Very <br /> N/A mph NO D2, E negligible N/A Heavy 32° NO Footnote g 2% 58.7° <br /> For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. <br /> a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code_ <br /> The weathering column shall be filled in with the weathering index (i. e, "negligible," `moderate" or "severe ") for concrete as determined <br /> from the Weathering Probability Map [Figure R301.2(3)]. The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C <br /> 73,C 90,C 129,C 145,C 216 or 652. <br /> b. The frost line depth may require deeper footings than indicated in Figure R403.1(1). The City of Pleasanton does not require additional <br /> depth of footing below tinish grade. <br /> c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local <br /> subterranean termite damage. <br /> d. The jurisdiction shall till in this part of the table with the wind speed from the basic wind speed map [FigureR301.2(4)]. W ind exposure <br /> category shall he determined on a site - specific basis in accordance with Section R301.2.1.4. <br /> e. The outdoor design dry -bulb temperature was selected from the columns of97%rpercent values for winter from Appendix D of the <br /> International Plumbing Code. <br /> f The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. <br /> g. The date of the City of Pleasanton's entry into the National Flood Insurance Program: May 5, 1971. <br /> The date(s) of the Flood Insurance Study: August 3, 2009; September 30, 1997; September 19. 1984; June 1980 revised August 31, 1982. <br /> The panel numbers and dates of all currently effective FIRMs adopted by the City of Pleasanton, as amended: Panel 06001CO304G; Panel <br /> 06001CO3086; Panel 06001CO3090, Panel 06001CO3 160; Panel 06001CO3170; Panel 06001003180; Panel 0600100319th Panel <br /> 06001CO3280: Panel 06001CO3366; Panel 06001CO3370: Panel 06001CO3390; Panel 06001CO3430: Panel 06001C04600: Panel <br /> 0600IC0476G; Panel 06001 C0480G; and Panel 06001C0485G, all effective August 3, 2009_ <br /> h. In accordance with Sections R905 2.7.1, R905.4.3.1, R905.5.3.1, R905.6.3.1,12905.7.3.1 and 12905.8.3.1. where there has been a history of <br /> local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall <br /> fill in this part of the table with "NO." <br /> i. The City of Pleasanton selected the 100 -year (99 %) value on the National Climatic Data Center data table "Air Freezing Index- USA <br /> Method (Base 32 °)" at www nede.noaa.gov /fpsfhtml. <br /> j. The City of Pleasanton selected the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index -USA <br /> Method (Base 32 °F)' at www.ncdc.noaagov /fpsf html. <br /> 42 <br />
The URL can be used to link to this page
Your browser does not support the video tag.