Laserfiche WebLink
A5.504.2.1.3 Noncomplying building areas. For each sampling area of the building exceeding the <br /> maximum concentrations specified in Section A5.504.2.1.1, flush out with outside air and retest samples <br /> taken from the same area. Repeat the procedures until testing demonstrates compliance. <br /> A5.504.4.6.1 Verification of compliance. Documentation shall be provided verifying that resilient <br /> flooring materials meet the pollutant emission limits. <br /> A5.504.4.7.1 Resilient flooring systems. For 100 percent of floor area scheduled to receive <br /> resilient flooring, install resilient flooring complying with the VOC- emission limits defined in the <br /> 2009 CHPS criteria and listed on its Low - emitting Materials List (or Product Registry) or certified <br /> under the FloorScore program of the Resilient Floor Covering Institute, <br /> A5.504.4.7.2 Verification of compliance. Documentation shall be provided verifying that resilient <br /> flooring materials meet the pollutant emission limits. <br /> A5.504.4.8.1 Thermal insulation, Tier 2. Install No -Added Formaldehyde thermal insulation in addition <br /> to meeting Section A5.504.4.8. <br /> A5.504.4.8.2 Veriflcation of compliance. Documentation shall be provided verifying that thermal <br /> insulation materials meet the pollutant emission limits. <br /> A5.504.4.9 Acoustical ceilings and wall panels. Comply with Chapter 8 in Title 24, Part 2 and with the <br /> VOC- emission limits defined in the 2009 CHPS criteria and listed on its Low - emitting Materials List (or <br /> Product Registry). <br /> A5.504.4.9.1 Verification of compliance. Documentation shall be provided verifying that acoustical <br /> finish materials meet the pollutant emission limits. <br /> A5.504.5 Hazardous particulates and chemical pollutants. Minimize and control pollutant entry into <br /> buildings and cross - contamination of regularly occupied areas. <br /> A5.504.5.1 Entryway systems. Install permanent entryway systems measuring at least six feet in the <br /> primary direction of travel to capture dirt and particulates at entryways directly connected to the outdoors <br /> as listed in Items 1 through 3 in Section A5.504.5.1. <br /> A5.504.5.2 Isolation of pollutant sources. In rooms where activities produce hazardous fumes or <br /> chemicals, exhaust them and isolate them from their adjacent rooms as listed in Items 1 through 3 in <br /> Section A5.504.5.2. <br /> A5.504.5.3.1 Filters. In mechanically ventilated buildings, provide regularly occupied areas of the building <br /> with air filtration media for outside and return air prior to occupancy that provides at least a MERV of 11. <br /> Environmental Comfort <br /> A5.507.1 Lighting and thermal comfort controls. Provide controls in the workplace as described in <br /> Sections A5.507.1.1 and A5.507.1.2. <br /> A5.507.1.1 Single- occupant spaces. Provide individual controls that meet energy use requirements in <br /> the 2007 California Energy Code by Sections A5.507.1.1.1 and A5.507.1.1.2. <br /> A5.507.1.1.1 Lighting. Provide individual task lighting and/or daylighting controls for at least 90 percent <br /> of the building occupants. <br /> A5.507.1.1.2 Thermal comfort. Provide individual thermal comfort controls for at least 50 percent of the <br /> building occupants by Items 1 and 2 in Section A5.507.1.1.2. <br /> A5.507.1.2 Multi- occupant spaces. Provide lighting and thermal comfort system controls for all shared <br /> multi- occupant spaces. <br /> A5.507.2 Daylight. Provide daylit spaces as required for toplighting and sidelighting in the 2007 <br /> California Energy Code. In constructing a design, consider Items 1 through 4 in Section A5.507.3. <br /> A5.507.3 Views. Achieve direct line of sight to the outdoor environment via vision glazing between 2 <br /> and 7'6" above finish floor for building occupants in 90 percent of all regularly occupied areas. <br /> A5.507.3.1 Interior office spaces. Entire areas of interior office spaces may be included in the <br /> calculation if at least 75 percent of each area has direct line of sight to perimeter vision glazing. <br /> A5.507.3.2 Multi-occupant spaces. Include in the calculation the square footage with direct line of sight <br /> to perimeter vision glazing. <br /> Outdoor Air Quality <br /> 5.508.1 Ozone depletion and global warming reductions. Installations of HVAC, refrigeration and fire <br /> suppression equipment shall comply with Sections 5.508.1.1 and 5.508.1.2. <br /> Note: This general informational handout is provided as a courtesy. Specific questions should be addressed to the project <br /> architect, contractor, other design professional, or by more detailed consideration of Pleasanton Municipal Code Chapter 20.26 and <br /> the California Green Building Standards Code (CALGreen 2010) at Title 24 Cal. Code of Regulations, Part 11. <br />