My WebLink
|
Help
|
About
|
Sign Out
AMERICANS WITH DISABILITIES TRANSITION PLAN 2008
City of Pleasanton
>
CITY CLERK
>
LONG TERM AGREEMENT
>
A
>
AMERICANS WITH DISABILITIES TRANSITION PLAN 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2018 10:50:48 AM
Creation date
2/16/2018 10:50:42 AM
Metadata
Fields
Template:
LONG TERM AGREEMENTS
LONG TERM AGREEMENTS - DOCUMENT DATE
2/2/2008
LONG TERM AGREEMENTS - NAME
TRANSITION PLAN FOR COMPLIANCE
LONG TERM AGREEMENTS - TYPE
MISC AGMT
LONG TERM AGREEMENTS - RECORD SERIES
704-06 (Long Term Agreements)
LONG TERM AGREEMENTS - DESTRUCTION DATE
PERMANENT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rCITY OF PLEASANTON Page 10 of 12 <br /> IV TRANSITION PLAN July 28, 2004 <br /> Updated February 1 , 2008 <br /> IDENTIFIED IMPROVEMENTS <br /> Location Barrier Removal #1 Barrier Removal #2 Barrier Removal#3 Barrier Removal #4 <br /> Library Curb ramps extend into Main service counters are Toilet stall doors swing into Emergency exit door from <br /> accessible parking spaces. 39"high,counters should be stall, required to swing out. the meeting room has a <br /> 36". threshold of greater than <br /> 1/2" <br /> Amador Recreation Center Entrance on North side has Outdoor seating does not Neither toilet facilities are Pass through window and <br /> 30"wide leaf and 28"cear have integrated wheelchair accessible by the disable. counter in kitchen are 40" <br /> opening. Req 32"clear. position. above floor Req 36"max. <br /> Amador Theatre Accessible ramp is to the No accessible route of travel In the men's restroom the Drinking fountain onset wing <br /> North of main entrance and to the balcony for the coat hook in the accessible id not accessible ADAAG <br /> is not obvious and visible. disable. stall is mounted 66"above requires hi/low fountain. <br /> the floor <br /> Aquatic Center Strike/pull side clearance to Showers in both restrooms Baby changing tables in Snack bar counter is 38" <br /> employee locker room is have designated accessible men and women restrooms above ground req to be 36" <br /> 11", req. 18 location but no bench or are 41"above floor req.to max <br /> hand held sprayers. be 36"max <br /> Gingerbread Pre-school Walkway to main entrance Outdoor play area requires Children's unisex toilet room Drinking fountains required <br /> has slope greater than a level ground area and has no disable accessible to be located within an <br /> 8 33%. accessible path. stalls. alcove <br /> Century House There are no disabled The doors within the The door to men's restroom The building has only one <br /> accessible parking spaces building include hardware has a width of 30" exit that is disabled <br /> identified. which requires grasping and accessible <br /> turning. <br /> Senior Center The curb ramp outside the There are 3 outdoor seating In the restrooms,the The building only has one <br /> main entrance has a 10 2% tables with attached chairs. accessible stall door drinking fountain and it is <br /> slope. there is no accessible hardware requires grasping not a high/low type. <br /> seating locations provided. and turning <br /> Tennis & Community Park The parking lot only has 4 The umbrellas in the tables Mirrors and dispensers in <br /> disabled accessible parking project beyond the table and all restrooms were mounted <br /> spaces, 5 are required for are less than 80"above the too high. <br /> that size lot. ground <br /> Veterans Hall The front entrance ramp is Many of the doors hardware Neither the men's nor Drinking fountain requires <br /> only 39"wide and the is not accessible, requiring women's restroom off the high/low unit because there <br /> landing area is less than the grasping or twisting lobby IS accessible or is only a single location <br /> required 72" (Completed) useable by the disabled. <br /> (Completed) <br /> Pleasanton Historical Museum The entrance ramp at the Some of the doors require Both restrooms have limited Signs that provide <br /> front has a slope that 10 pounds of push to open accessible features.The information and direction <br /> exceeds the maximum entrance door has 27"clear are required to have raised <br /> 8 33%. opening. letters and Braille symbols <br />
The URL can be used to link to this page
Your browser does not support the video tag.