My WebLink
|
Help
|
About
|
Sign Out
7_Exhibits A, C & D
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2021
>
07-14
>
7_Exhibits A, C & D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2021 3:26:25 PM
Creation date
7/7/2021 3:26:02 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
7/14/2021
DESTRUCT DATE
15Y
Document Relationships
7
(Message)
Path:
\BOARDS AND COMMISSIONS\PLANNING\AGENDA PACKETS\2020 - PRESENT\2021\07-14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Tracking System (SMARTS) website. A Qualified SWPPP Developer (QSD) and a <br /> Qualified SWPPP Practitioner (QSP) must be responsible for permit compliance. The <br /> SMARTS system will generate a Waste Dischargers Identification (WDID) number, <br /> which must be printed on the grading and/or erosion control plans. (Address this <br /> condition prior to Grading and/or Building Permit issuance.) <br /> 53. DRIVEWAYS AND SIDEWALKS: New driveway approaches to the site shall be <br /> constructed in conformance with Drawing 106 for Type "A" City standard approaches. The <br /> meandering sidewalk shall be constructed in conformance with Drawing 101 for Type "A" <br /> City sidewalk. (Address this condition prior to Encroachment Permit issuance.) <br /> 54. MUNICIPAL REGIONAL PERMIT: Because the project creates or replaces more than <br /> 10,000 SF of impervious surface, it is considered a Regulated Project according to <br /> Provision C.3.b of the San Francisco Bay Region Municipal Regional Stormwater NPDES <br /> Permit (Order No. R2-2015-0049, NPDES Permit No. CAS612008, adopted 11/19/2015, or <br /> most current version if superseded). The project is also considered a Hydromodification <br /> Management (HM) project. As such, design of NPDES features shall be in accordance <br /> with the applicant's submitted Bay Area Hydraulic Model (BAHM) 2013 Project Report, <br /> and the Alameda Countywide Clean Water Program's C.3 Technical Guidance Manual. <br /> (Address this condition prior to Grading and/or Building Permit issuance.) <br /> 55. PARKING DIMENSIONS: Parking space dimensions shall be consistent with Table <br /> 18.88.040 of the Pleasanton Municipal Code, although a front bumper overhang can be <br /> utilized to reduce the space length up to two feet where parking abuts a landscaping area. <br /> In addition, the ratio of compact to standard-sized spaces shall not exceed the 40% <br /> threshold described in Code §18.88.040(A)(3). (Address this condition prior to Building <br /> Permit issuance.) <br /> 56. PUBLIC SERVICES EASEMENT DEDICATION: The applicant shall dedicate an 12-foot <br /> wide Public Services Easement (PSE) along the property's Dublin Canyon Road frontage <br /> on Parcel Map 10539, or shall dedicate said PSE by separate instrument if the parcel <br /> map is not recorded prior to issuance of an Occupancy Permit for any on-site building. <br /> (Address this condition prior to issuance of an Occupancy Permit.) <br /> Standard Conditions of Approval: <br /> 57. DESIGN PER CITY STANDARDS: All public improvements shall be designed in <br /> compliance with the City Standard Specifications and Details in effect at the time of the <br /> issuance of the encroachment, grading, or subdivision permit, whichever occurs first. <br /> (Address this condition prior to Encroachment Permit issuance.) <br /> 58. CONDITIONS OF APPROVAL: The Conditions of Approval shall be depicted on a plan <br /> sheet(s) in the improvement plans. (Address this condition prior to Building Permit <br /> issuance.) <br /> 59. GEOTECHNICAL CONSULTANT — DESIGN CERTIFICATION: The applicant shall <br /> comply with the recommendations of the project geotechnical report. The applicant's <br /> PUD-114-01M& P20-0995 Planning Commission <br /> Page 11 of 25 <br />further excavation or disturbance of the site or any nearby area reasonably <br /> suspected to overlie adjacent remains until the County coroner has determined, in <br /> accordance with any law concerning investigation of the circumstances, the manner and <br /> PUD-114-01M& P20-0995 Planning Commission <br /> Page 8 of 25 <br /> April 15, <br /> and from August 15 through October 30, in order to avoid take of non-volant <br /> (non—flying or inactive, either young, or seasonally torpid) individuals. <br /> PUD-114-01M& P20-0995 Planning Commission <br /> Page 3 of 25 <br />YCROSSCRISFIELD .*- 4-; -,47÷-'' 1.1--1 ''.-. HAM <br /> ;-----fk;s7,4G <br /> il <br /> 3` <br /> • kst • .7 <br /> I DIJNIYA1:1%, ..4.. ,i4is' '1 , „J 10 ,,,... <br /> ‘1 'kTIAV - 1) \ ‘ ' ?) $.Y \t, ,2:2/ <br /> \ ‘ 111-,-,: . <br /> ,..... i ..., i <br /> 1:11,343 <br /> o 0.125 0.25 mi PUD-140, Townsend, Lot Line, 2207 Martin Ave Planning Division =-- -.• .-.... , 1:16 <br /> I i II May 10,2021 FLEA:.,ANTON. <br /> 0 650 1,300 Feet <br />