|
0602516 NFPA Required Loose Equipment,
<br />Pumper, NFPA 2016, Provided by
<br />Fire Department
<br />NFPA REQUIRED LOOSE EQUIPMENT PROVIDED BY FIRE DEPARTMENT
<br />The following loose equipment as outlined in NFPA 1901, 2016 edition, section 5.9.3 and 5.9.4
<br />will be provided by the fire department.
<br />800 ft (60 m) of 2.50" (65 mm) or larger fire hose.
<br />400 ft (120 m) of 1.50" (38 mm), 1.75" (45 mm), or 2.00" (52 mm) fire hose.
<br />One (1) handline nozzle, 200 gpm (750 L/min) minimum.
<br />Two (2) handline nozzles, 95 gpm (360 L/min) minimum.
<br />One (1) smoothbore of combination nozzle with 2.50" shutoff that flows a minimum of 250 gpm.
<br />One (1) SCBA complying with NFPA 1981 for each assigned seating position, but not fewer than
<br />four (4), mounted in brackets fastened to the apparatus or stored in containers supplied by the
<br />SCBA manufacturer.
<br />One (1) spare SCBA cylinder for each SCBA carried, each mounted in a bracket fastened to the
<br />apparatus or stored in a specially designed storage space(s).
<br />One (1) first aid kit.
<br />Four (4) combination spanner wrenches.
<br />Two (2) hydrant wrenches.
<br />One (1) double female 2.50" (65 mm) adapter with National Hose threads.
<br />One (1) double male 2.50" (65 mm) adapter with National Hose threads.
<br />One (1) rubber mallet, for use on suction hose connections.
<br />Two (2) salvage covers each a minimum size of 12 ft x 14 ft (3.7 m x 4.3 m).
<br />One (1) traffic vest for each seating position, each vest to comply with ANSI/ISEA 207, Standard
<br />for High Visibility Public Safety Vests, and have a five-point breakaway feature that includes two
<br />(2) at the shoulders, two (2) at the sides, and one (1) at the front.
<br />Five (5) fluorescent orange traffic cones not less than 28.00" (711 mm) in height, each equipped
<br />with a 6.00" (152 mm) retro-reflective white band no more than 4.00" (152 mm) from the top of
<br />the cone, and an additional 4.00" (102 mm) retro-reflective white band 2.00" (51 mm) below the
<br />6.00" (152 mm) band.
<br />Five (5) illuminated warning devices such as highway flares, unless the five (5) fluorescent
<br />orange traffic cones have illuminating capabilities.
<br />One (1) automatic external defibrillator (AED).
<br />Four (4) ladder belts meeting the requirements of NFPA 1983, Standard on Fire Service Life
<br />Safety Rope and System Components (if equipped with an aerial device).
<br />If the supply hose carried does not use sexless couplings, an additional double female adapter
<br />and double male adapter, sized to fit the supply hose carried, will be carried mounted in brackets
<br />fastened to the apparatus.
<br />If none of the pump intakes are valved, a hose appliance that is equipped with one or more gated
<br />intakes with female swivel connection(s) compatible with the supply hose used on one side and a
<br />swivel connection with pump intake threads on the other side will be carried. Any intake
<br />connection larger than 3.00" (75 mm) will include a pressure relief device that meets the
<br />requirements of 16.6.6.
<br />If the apparatus does not have a 2.50" National Hose (NH) intake, an adapter from 2.50" NH
<br />female to a pump intake will be carried, mounted in a bracket fastened to the apparatus if not
<br />already mounted directly to the intake.
<br />If the supply hose carried has other than 2.50" National Hose (NH) threads, adapters will be
<br />carried to allow feeding the supply hose from a 2.50" NH thread male discharge and to allow the
<br />hose to connect to a 2.50" NH female intake, mounted in brackets fastened to the apparatus if not
<br />already mounted directly to the discharge or intake.
<br />0519913 Not Required, Soft Suction Hose
<br />
<br />SOFT SUCTION HOSE
<br />There will be no soft suction hose provided.
<br />0602390 Strainer, Provided by Fire
<br />Department, Pumper NFPA 2016
<br />Classification
<br />STRAINER PROVIDED BY FIRE DEPARTMENT
<br />NFPA 1901, 2016 edition, section 5.8.2.1.1 requires a suction strainer when suction hose is
<br />provided.
<br />The strainer is not on the apparatus as manufactured. The fire department will provide the suction
<br />strainer.
<br />0602538 Extinguisher, Dry Chemical, Pumper
<br />NFPA 2016 Class, Provided by Fire
<br />Department
<br />DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
<br />NFPA 1901, 2016 edition, section 5.9.4 requires one (1) approved dry chemical portable fire
<br />extinguisher with a minimum 80-B:C rating mounted in a bracket fastened to the apparatus.
<br />The extinguisher is not on the apparatus as manufactured. The fire department will provide and
<br />mount the extinguisher.
<br />0602360 Extinguisher, 2.5 Gal. Pressurized
<br />Water, Pumper NFPA 2016,Provided
<br />by Fire Dept
<br />WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
<br />NFPA 1901, 2016 edition, section 5.9.4 requires one (1) 2.5 gallon or larger water extinguisher
<br />mounted in a bracket fastened to the apparatus.
<br />The extinguisher is not on the apparatus as manufactured. The fire department will provide and
<br />mount the extinguisher.
<br />0602679 Axe, Flathead, Pumper NFPA 2016
<br />Classification, Provided by Fire
<br />Department
<br />FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT
<br />NFPA 1901, 2016 edition, Section 5.9.4 requires one (1) flathead axe mounted in a bracket
<br />fastened to the apparatus.
<br />The axe is not on the apparatus as manufactured. The fire department will provide and mount the
<br />axe.
<br />59717Bid #:
|