Table 3-6: System-Wide Peaking Factors <br />Line System Peaking Factor, Peaking Factor Base Max Dav Max Hour <br />1 Base 1.00 100% 0% 0% 100% <br />2 Max Day 1.40 71% 29% 0% 100% <br />3 Max Hour 2.50 40% 16% 44% 100% <br />4 Average Max Day/Max Hour 56% 22% 22% 100% <br />Table 3-7 shows the customer class-specific peaking factors based on the maximum bi-monthly usage divided by <br />average bi-monthly usage for each class and tier. This peaking factor is used as a proxy for the class and tier- <br />specific Max Day peaking factors(Column B),which are based on the current tiers. The Max Hour peaking factor <br />is calculated based on the relative factor from the system-wide peaking factors. <br />For example,the Residential class Max Hour peaking factor(Column C, Line 1)is calculated as follows: <br />Residential Max Day Peaking Factor[BI]x(System-wide Max Hour peakingfactor[Table 3-6,B3]/System-side Max Day <br />peakingfactor[Table 3-6,B21)=Residential Max Hour peaking factor[CI] <br />Table 3-7: Class-Specific Peaking Factors <br />Line Customer Class <br />Max Day Max Hour <br />PeakiMFactor Peaking <br />1 Single Family Residential 1.71 3.05 <br />2 Tier 1 1.22 2.18 <br />3 Tier 2 1.98 3.53 <br />4 Tier 3 2.42 4.32 <br />5 Tier 4 2.62 4.68 <br />6 Multi-Family Residential 1.19 2.13 <br />7 Commercial/Industrial 1.30 2.33 <br />8 Irrigation 1.99 3.55 <br />9 Recycled Water Irrigation 2.17 3.87 <br />3.6. Peak Capacity <br />Table 3-8 shows the calculation of additional capacity required to meet Max Day and Max Hour demands. The <br />Max Day(Column D)and Max Hour(Column G)were derived in the previous subsection(Table 3-7)for each <br />customer class and tier. <br />Annual use(Column B)is derived from the water usage projections(Table 2-6)based on the current tiers.Note <br />that the total annual use for each class(Column B,Lines 1, 6-10)are equal to the total water use for each class in <br />the projections.Annual use is then converted to average daily use(Column C), assuming 365 days in a year. <br />The Max Day capacity in ccf per day(Column E)is calculated by multiplying the average daily use(Column C)by <br />the Max Day peaking factors(Column D). The Max Day extra capacity in ccf per day(Column F)is equal to the <br />Max Day capacity(Column E)less average daily use(Column C). <br />38 CITY OF PLEASANTON
The URL can be used to link to this page
Your browser does not support the video tag.