Laserfiche WebLink
December 21, 2022 <br /> Job No. 4031.101 <br /> Page 9 <br /> <br />BERLOGAR STEVENS & ASSOCIATES <br /> <br /> <br /> RETAINING WALLS <br /> <br />Retaining walls can be of conventional cantilever or gravity type. The following geotechnical <br />criteria should be used for the retaining wall designs: <br /> <br />7.11.1. Lateral Earth pressures <br /> <br />Backfill soils for cantilever-type concrete or masonry walls should have a PI of 20 or less for soil <br />placed within 5 feet of the wall. The following are our recommended lateral earth pressures for <br />retaining walls: <br /> <br />Active Equivalent Fluid Pressure (Level backfill and drained conditions) 55 pcf <br />Active Equivalent Fluid Pressure (3H:1V backfill and drained conditions) 65 pcf <br />Active Equivalent Fluid Pressure (2H:1V backfill and drained conditions) 100 pcf <br />At-Rest Equivalent Fluid Pressure (Level backfill and drained conditions) 80 pcf <br />Seismic Equivalent Fluid Pressure – Walls Retaining More than 6 Feet (in <br />addition to active equivalent fluid pressure, SEAOC 2010 1) <br />80 pcf <br /> <br />Surcharge Load, where applicable Designated by structural engineer <br /> <br /> <br />For terraced walls, the lower wall should be designed to support the backfill and the load from <br />upper wall. For the walls retaining more than 6 feet, the total pressure computed would act on the <br />wall as the same location as the initial static pressure; i.e., the resultant would act at a height of <br />H/3 above the base. <br /> <br /> <br />7.11.2. Retaining Wall Foundations <br /> <br />Conventional retaining walls can be supported on shallow foundations. The following may be <br />used to design the retaining wall foundations: <br /> <br />Allowable Bearing Capacity (DL + LL) <br />(may be increased by one-third for seismic and wind loads at the discretion of the <br />structural engineer) <br />2,500 psf <br />Allowable Passive Equivalent Fluid Pressure (neglect the upper 2 feet) * 350 pcf <br />Allowable Base Friction Coefficient * 0.25 <br />Minimum Footing Depth 2 feet <br />* no reduction is required when combining passive resistance and friction <br /> <br /> <br /> <br /> <br /> <br /> <br />1 SEOC 2010 Convention Proceedings, 2010. Seismic Earth Pressures on Deep Building Basements.