My WebLink
|
Help
|
About
|
Sign Out
CITY COUNCIL REGULAR MEETING AGENDA PACKET
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2024
>
111924 REGULAR
>
CITY COUNCIL REGULAR MEETING AGENDA PACKET
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/17/2026 12:24:12 PM
Creation date
11/13/2024 3:02:35 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
11/19/2024
DESTRUCT DATE
15Y
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
420
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Engineering Data Summary <br />Replacement Fuses <br />Drive input fuses are recommended to disconnect the drive from power in the event that a component <br />fails in the drive’s power circuitry. Recommended drive input fuse specifications are listed in the <br />Submittal Schedule Details and in the Fuse Ratings Table. Fuse rating information is provided for <br />customer reference. <br />Item Catalog Number Drive Input Fuse Ratings <br />Amps (600V) Bussmann Type <br />1 ACQ580-01-124A-4 200 JJS-200 <br />Terminal Sizes / Cable Connection Requirements <br />Power and motor cable terminal sizes and connection requirements are shown in the Submittal <br />Schedule Details and in the Terminal Sizes / Cable Connection Requirements Table. The information <br />provided below is for connections to input power and motor cables. These connections may be made <br />to an input circuit breaker or disconnect switch, a motor terminal block, overload relay, and/or directly <br />to bus bars and ground lugs. The table also lists torque that should be applied when tightening <br />terminals and spacing requirements where multiple mounting holes are provided in the bus bar. <br />Item Catalog Number Input Wiring Output Wiring Ground <br />Wiring <br />1 ACQ580-01-124A-4 <br /> 4 AWG (25 <br />mm^2) <br />22.1 lbf-ft (30 <br />Nm) <br /> 4 AWG (25 <br />mm^2) <br />22.1 ft-lb (30 N- <br />m) <br /> 350 MCM (185 <br />mm^2) <br />7.2 ft-lb (9.8 N- <br />m) <br />Heat Dissipation Requirements <br />The cooling air entering the drive must be clean and free from corrosive materials. The Submittal <br />Schedule Details and the Heat Dissipation Requirements table below give the heat dissipated into the <br />hot air exhausted from the drives. If the drives are installed in a confined space, the heat must be <br />removed from the area by ventilation or air conditioning equipment. <br />Item Catalog Number Watts BTU/Hr <br />1 ACQ580-01-124A-4 1476 5,033 <br />Dimensions and Weights <br />Dimensions and weights of the drives provided are given in the Submittal Schedule Details and in the <br />Dimensions and Weights Table. The table also lists the applicable dimension drawings that include <br />additional detail. Dimension drawings may be provided in the back of this submittal. <br />Item Catalog Number Height <br />mm <br />(in) <br />Width <br />mm <br />(in) <br />Depth <br />mm <br />(in) <br />Weight <br />kg <br />(lbs) <br />1 ACQ580-01-124A-4 727 <br />(28.63) <br />252 <br />(9.93) <br />369 <br />(14.53) <br />42.4 <br />(94) <br /> <br />Free Space Requirements, Standalone <br />Free Space Requirements for standalone mounting. <br /> <br />Item Catalog Number <br />Standalone, <br />Above <br />mm <br />(in) <br />Standalone, <br />Below <br />mm <br />(in) <br />Standalone, <br />Sides <br />mm <br />(in) <br />1 ACQ580-01-124A-4 155 <br />(6.11) <br />300 <br />(11.82) <br />150 <br />(5.91) <br /> <br />Page 215 of 658
The URL can be used to link to this page
Your browser does not support the video tag.