The City of Pleasanton has adopted the California Fire Code with some local amendments as their fire code. One <br />amendment, Section 20.24.187, amends the definition of the Wildland Urban Interface to the area defined by CAL <br />FIRE fire hazard severity zone maps. <br />California Code of Regulations <br />Title 24 California Fire Code <br />The California Fire Code establishes minimum requirements consistent with nationally recognized good practices <br />to safeguard the public health, safety, and general welfare from the hazards of fire, explosions, or dangerous <br />conditions in new and existing buildings, structures, and premises and to provide safety and assistance to <br />firefighters and emergency responders during emergency operations. Chapter 5 of the fire code describes fire <br />service features for buildings, structures, and premises that contain the requirements for access roads for fire <br />department apparatus. These requirements include horizontal and vertical clearance requirements for roadside <br />vegetation. Chapter 49 of the fire code provides minimum standards to reduce the likelihood of life and property <br />loss due to wildfire. It includes prescriptive requirements for the installation and maintenance of vegetation near <br />buildings. Chapter 49 also includes the requirement that new developments or projects in the identified WUI area <br />prepare a fire prevention plan, known as a Wildland Fire Management Plan to the LPFD, that describes the <br />measures taken to minimize and mitigate the wildfire risk on the project property. <br />California Government Code <br />Sections 51175 through 51189 of the California government code define the areas of the state where a local <br />agency is responsible for fire protection and where a very high fire hazard exists. These sections also define the <br />responsibility of property owners to maintain the buildings and vegetation on their property within 100 feet of a <br />structure in a condition that minimizes the risk of building ignition. Section 51182 provides specific criteria for <br />maintaining vegetation within 100 feet of a building, including trees that overhang a building. These sections form <br />the core regulations that define the vegetation management standards enforced by the fire department. <br />Utility Clearance Requirements <br />Public Utility Code <br />General Order 95 <br />General Order 95, Rule 37, Table 1 defines the above -ground clearances of conductors and the clearances between <br />conductors and other structures/vegetation (Figure 3). These rules include the maintenance of trees near electrical <br />equipment and special provisions for clearances in WUI or areas designated as high fire hazard severity zones. <br />APPENDIX A -WILDFIRE <br />16 of 219 <br />