Attachment 1 Exhibit B <br />Page 31 of 64 <br />CFC Section 5001.5.1.1 added - Hazardous Materials Management Plan (HMMP). <br /> <br />Section 5001.1.1 is added to read: <br /> <br />5001.5.1.1 Hazardous Materials Management Plan (HMMP). The HMMP shall comply with <br />California Health and Safety Code, Chapter 6.95, Sections 25500 through 25545, and California Code <br />of Regulations, Title 19, Division 2, Chapter 4. <br /> <br />CFC Section 5001.5.2.1 added - Hazardous Materials Inventory Statement (HMIS). <br /> <br />Section 5001.2.1 is added to read: <br /> <br />5001.5.2.1 Hazardous Materials Inventory Statement (HMIS). The HMIS shall comply with <br />California Health and Safety Code, Chapter 6.95, Sections 25500 through 25545, and California Code <br />of Regulations, Title 19, Division 2, Chapter 4. <br /> <br /> <br />20.24.195 CFC Section 5001.5.3 added – Hazardous Materials Business Plan (HMBP) Reporting <br />Thresholds. <br />Section 5001.5.3 is added as follows: <br />In addition to the reporting requirements of California Health and Safety Code, Chapter 6.95, <br />Sections 25500 through 25545, and California Code of Regulations, Title 19, Division 2, Chapter 4, <br />regulated facilities are required to report any amount of highly toxic, toxic, and moderately toxic <br />gases, oxidizing materials Class 4, oxidizing materials Class 3, unstable (reactive) Class 4, unstable <br />(reactive) Class 3, pyrophoric materials, water reactive Class 3. <br /> <br />20.24.200 CFC Section 5003.2.10 added – Biodiesel and methanol equipment. <br /> <br />Section 5003.2.10 is added to read: <br /> <br />5003.2.10 Biodieseland methanol equipment. Biodiesel and methanol manufacturing/processing <br />equipment shall be listed or approved. Such equipment shall at a minimum adequately address <br />electrical system, materials of construction, ventilation, seismic and process control and shut-down <br />safety issues. <br /> <br />20.24.210 CFC Section 5003.5.2 added – Ventilation ducting. <br /> <br />Section 5003.5.2 is added to read: <br /> <br />5003.5.2 Ventilation ducting. Product conveying ducts for venting hazardous materials operations <br />shall be labeled with the hazard class of the material being vented and the direction of flow. <br /> <br />20.24.220 CFC Section 5003.5.3 added – H Occupancies. <br /> <br />Section 5003.5.3 is added to read: <br /> <br />5003.5.3 H Occupancies. In “H” occupancies, all piping and tubing may be required to be identified <br />when there is any possibility of confusion with hazardous materials transport tubing or piping. The <br />Page 42 of 376