My WebLink
|
Help
|
About
|
Sign Out
CITY COUNCIL REGULAR AGENDA PACKET
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2025
>
100725 REGULAR
>
CITY COUNCIL REGULAR AGENDA PACKET
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2025 3:27:07 PM
Creation date
10/10/2025 3:21:29 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
10/7/2025
DESTRUCT DATE
15Y
DOCUMENT NO
CITY COUNCIL REGULAR MEETING AGENDA PACKET 10/7/25
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Attachment 1 Exhibit B <br />Page 34 of 64 <br /> <br />Table 6004.1 <br />Minimum Threshold Quantities for Highly Toxic, Toxic and Moderately Toxic Gases <br /> <br />Highly Toxic 0 cubic feet <br />Toxic 10 cubic feet <br />Moderately Toxic 20 cubic feet <br /> <br />20.24.300 CFC Section 6004.1.2 amended – Gas Cabinets. <br /> <br />Section 6004.1 is hereby amended as follows: <br /> <br />6004.1.2 Gas cabinets. Gas cabinets containing highly toxic, toxic or moderately toxic gases shall <br />comply with Section 5003.8.6 and the following requirements: <br />[balance to remain the same] <br /> <br />20.24.310 CFC Section 6004.1.3 amended – Exhausted Enclosures. <br /> <br />Section 6004.1.3 is hereby amended as follows: <br /> <br />6004.1.3 Exhausted enclosures. Exhausted enclosures containing highly toxic, toxic or moderately <br />toxic gases shall comply with Section 5003.8.5 and the following requirements: <br />[balance to remain the same] <br /> <br />20.24.320 CFC Sections 6004.1.4 added – Automatic shut-off valve. <br /> <br />Section 6004.1.4 is added to read: <br /> <br />6004.1.4 Automatic shut-off valve. An automatic shut-off valve, which is of a fail-safe to close <br />design, shall be provided to shut off the supply of highly toxic gases as close as possible to the supply <br />container for any of the following: <br />1. Activation of a manual fire alarm system. <br />2. Activation of the gas detection system. <br />3. Failure of emergency power. <br />4. Failure of primary containment. <br />5. Seismic activity. <br />6. Failure of required ventilation. <br />7. Manual activation at an approved remote location. <br /> <br />20.24.330 CFC Section 6004.1.5 added – Annual Maintenance. <br /> <br />Section 6004.1.5 is added to read: <br /> <br />6004.1.5 Annual Maintenance. All safety control systems at a facility shall be maintained in good <br />working condition and tested not less frequently than annually. Maintenance and testing shall be <br />performed by persons qualified to perform the maintenance and tests. Maintenance records and <br />certifications shall be kept for a minimum of three years and shall be made available to any <br />representative of the Livermore-Pleasanton Fire Department for inspection upon request. <br />Page 45 of 376
The URL can be used to link to this page
Your browser does not support the video tag.