My WebLink
|
Help
|
About
|
Sign Out
ITEM 5 EXHIBITS A-H
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2025
>
11-12
>
ITEM 5 EXHIBITS A-H
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2025 5:53:56 PM
Creation date
11/7/2025 5:11:43 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
11/12/2025
DESTRUCT DATE
15Y
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1327
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Page 23 <br /> <br />73. FIRE SPRINKLERS: Automatic fire sprinklers shall be installed in all occupancies in <br />accordance with the 2016 Pleasanton Building, Fire and Residential Codes with local <br />amendments and ordinances. <br /> <br />74. EMERGENCY RESPONDER RADIO: Emergency responder radio coverage shall be <br />provided in accordance with section 510 of the Fire Code. <br /> <br />75. FIRE PROTECTION FACILITIES: Prior to any construction framing, the applicant shall <br />provide adequate fire protection facilities, including, but not limited to a water supply <br />and water flow in conformance to the City's Fire Department Standards able to <br />suppress a major fire. <br /> <br />76. WATER FLOW AND CONTROL VALVES: All fire sprinkler system water flow and <br />control valves shall be complete and serviceable prior to final inspection. Prior to the <br />occupancy of a building having a fire alarm system, the Fire Department shall test and <br />witness the operation of the fire alarm system. <br /> <br />77. ELECTRICAL CONDUIT: Electrical conduit shall be provided to each fire protection <br />system control valve including all valve(s) at the water connections. The Livermore- <br />Pleasanton Fire Department requires electronic supervision of all valves for automatic <br />sprinkler systems and fire protection systems. <br /> <br />78. LISTED: All commercial, industrial, and multi-family residential occupancies shall have <br />valve tamper and water flow connected to a listed Central Station Service in <br />accordance with NFPA 72. Fire Department plan check includes specifications, <br />monitoring, installation, and alarm company certificates. Fire alarm control panel and <br />remote annunciation shall be at location(s) approved by the Fire Prevention Bureau. <br />All systems shall be point identified by individual device and annunciated by device <br />type and point. <br /> <br />79. HAZARDOUS MATERIALS: Should any operation or business activity involve the use, <br />storage or handling of hazardous materials, the firm shall be responsible for <br />contacting the Livermore-Pleasanton Fire Department prior to commencing <br />operations. Please contact the Hazardous Materials Coordinator at 925/454-2361. <br /> <br />80. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives shall <br />be designated as fire lanes and identified as such by red curb striping and posted with <br />signs at locations approve by the Fire Department. Signs shall be according to State <br />standards and read “No Parking – Fire Lane” and must be shown on the plans. The <br />red curb striping, sign location(s), and sign language shall be included in the building <br />permit submittal for review and approval by the Livermore-Pleasanton Fire <br />Department prior to building permit issuance <br /> <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.