My WebLink
|
Help
|
About
|
Sign Out
PC-2025-16
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2025
>
PC-2025-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2025 10:30:44 AM
Creation date
12/23/2025 10:28:35 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
7/23/2025
DESTRUCT DATE
PERMANENT
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ENGEO <br /> INCORPORATED <br /> <br /> <br />5150.100.101 <br />May 2, 2008 Page 23 <br />9. RETAINING WALLS <br /> <br />Due to the anticipated seepage at the cuts for the walls, temporary vertical cuts may not be <br />stable. This condition may necessitate temporary shoring or top-down wall construction such as <br />soil nail or cement-soil mixed walls. <br /> <br />9.1 LATERAL SOIL PRESSURES <br /> <br />Design proposed retaining walls to resist lateral earth pressures from adjoining natural materials <br />and/or backfill and from any surcharge loads. Provided that adequate drainage is included as <br />recommended below, design walls restrained from movement at the top to resist an equivalent <br />fluid pressure of 65 pounds per cubic foot (pcf). In addition, design restrained walls to resist an <br />additional uniform pressure equivalent to one-half of any surcharge loads applied at the surface. <br /> <br />Design unrestrained retaining walls with adequate drainage to resist an equivalent fluid pressure <br />of 50 pcf plus one-third of any surcharge loads. <br /> <br />The above lateral earth pressures assume level backfill conditions and sufficient drainage behind <br />the walls to prevent any build-up of hydrostatic pressures from surface water infiltration and/or a <br />rise in the groundwater level. If adequate drainage is not provided, we recommend that an <br />additional equivalent fluid pressure of 40 pcf be added to the values recommended above for <br />both restrained and unrestrained walls. Damp-proofing the walls should be included in areas <br />where wall moisture would be problematic. <br /> <br />Construct a drainage system, as recommended below, to reduce hydrostatic forces behind the <br />retaining wall. <br />
The URL can be used to link to this page
Your browser does not support the video tag.