My WebLink
|
Help
|
About
|
Sign Out
Planning Commission Meeting Agenda Packet (2)
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2025
>
05-14
>
Planning Commission Meeting Agenda Packet (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2025 3:16:17 PM
Creation date
12/30/2025 3:10:56 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> <br />P24-0420 and P24-0421 PC-2025-10, May 14, 2025 <br /> <br />to be submitted by the applicant in a format that integrates with ArcGIS by ESRI. The <br />“Digital Submittal Requirements” are available for download at the following weblink: <br /> <br /> https://www.cityofpleasantonca.gov/gov/depts/gis.asp <br /> <br />(Address this condition prior to acceptance of improvement or issuance of an <br />Occupancy Permit) <br /> <br />FIRE DEPARTMENT – 925-454-2361 <br /> <br />The Fire Prevention Bureau reviews building/civil drawings for conceptual on-site fire mains <br />and fire hydrant locations only. Plan check comments and approval DO NOT include: 1.) <br />Installation of the on-site fire mains and fire hydrants. Specific installation drawings submitted <br />by the licensed underground fire protection contractor shall be submitted to the Fire Prevention <br />Bureau for approval; and 2.) Backflow prevention or connections to the public water mains. <br /> <br />79. FIRE HAZARDS: The project developer shall keep the site free of fire hazards from the <br />start of lumber construction until the final inspection. <br /> <br />80. FIRE CODE: All construction shall conform to the requirements of the 2016 Pleasanton <br />Fire Code and local ordinances. All required permits shall be obtained prior to work <br />commencement. <br /> <br />81. SITE SAFETY: Site safety during construction shall be in accordance with Fire Code <br />chapter 33. <br /> <br />82. FIRE SPRINKLERS: Automatic fire sprinklers shall be installed in all occupancies in <br />accordance with the 2016 Pleasanton Building, Fire and Residential Codes with local <br />amendments and ordinances. <br /> <br />83. FIRE PROTECTION FACILITIES: Prior to any construction framing, the applicant shall <br />provide adequate fire protection facilities, including, but not limited to a water supply and <br />water flow in conformance to the City's Fire Department Standards able to suppress a <br />major fire. <br /> <br />84. WATER FLOW AND CONTROL VALVES: All fire sprinkler system water flow and <br />control valves shall be complete and serviceable prior to final inspection. Prior to the <br />occupancy of a building having a fire alarm system, the Fire Department shall test and <br />witness the operation of the fire alarm system. <br /> <br />85. ELECTRICAL CONDUIT: Electrical conduit shall be provided to each fire protection <br />system control valve including all valve(s) at the water connections. The Livermore- <br />Pleasanton Fire Department requires electronic supervision of all valves for automatic <br />sprinkler systems and fire protection systems. <br /> <br />86. LISTED: All commercial, industrial, and multi-family residential occupancies shall have <br />valve tamper and water flow connected to a listed Central Station Service in accordance
The URL can be used to link to this page
Your browser does not support the video tag.