Laserfiche WebLink
<br />Page 16 <br /> <br />66. SITE SAFETY: Site safety during construction shall be in accordance with Fire Code chapter <br />33. <br />67. FIRE SPRINKLERS: Automatic fire sprinklers shall be installed in all occupancies in <br />accordance with the 2022 Pleasanton Building, Fire and Residential Codes with local <br />amendments and ordinances. <br />68. FIRE PROTECTION FACILITIES: Prior to any construction framing, the applicant shall <br />provide adequate fire protection facilities, including, but not limited to a water supply and <br />water flow in conformance to the City's Fire Department Standards able to suppress a major <br />fire. <br />69. WATER FLOW AND CONTROL VALVES: All fire sprinkler system water flow and control <br />valves shall be complete and serviceable prior to final inspection. Prior to the occupancy of <br />a building having a fire alarm system, the Fire Department shall test and witness the <br />operation of the fire alarm system. <br />70. ELECTRICAL CONDUIT: Electrical conduit shall be provided to each fire protection system <br />control valve including all valve(s) at the water connections. The Livermore-Pleasanton Fire <br />Department requires electronic supervision of all valves for automatic sprinkler systems and <br />fire protection systems. <br />71. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than 300 feet in <br />industrial and commercial developments. Fire hydrants shall be installed at spacing not <br />greater than 400 feet in residential developments. <br />72. FIRE LANE MARKING: On-site access ways, turnarounds, and internal drives shall be <br />designated as fire lanes and identified as such by red curb striping and posted with signs at <br />locations approve by the Fire Department. Signs shall be according to State standards and <br />read “No Parking – Fire Lane” and must be shown on the plans. The red curb striping, sign <br />location(s), and sign language shall be included in the building permit submittal for review <br />and approval by the Livermore-Pleasanton Fire Department prior to building permit <br />issuance. <br />a. The following schedule for NO PARKING signs shall apply: <br />Width Requirements <br />36 feet or greater No requirements <br />Between 28 and 36 feet Post one side <br />Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />Cul-de-Sac Not permitted <br />73. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 inches <br />unobstructed vertical clearance, 20 feet of unobstructed width (26 feet where occupied <br />building floors exceed 30 feet height), and inside turning radius of 31 feet and outside <br />turning radius of 51 feet. Unobstructed shall mean a clear travel way, excluding parking <br />width, and designed for an emergency vehicle weight of 70,000 pounds under all weather <br />conditions. Unobstructed width shall not include the width of rolled curbs, sidewalks, or non- <br />drivable surfaces. All exterior portions of buildings must be within 200 feet of an access