My WebLink
|
Help
|
About
|
Sign Out
Planning Commission meeting agenda packet 7-9-25
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2025
>
07-09
>
Planning Commission meeting agenda packet 7-9-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2025 3:39:07 PM
Creation date
12/30/2025 3:30:31 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1025
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Page 16 <br /> <br />66. SITE SAFETY: Site safety during construction shall be in accordance with Fire Code chapter <br />33. <br />67. FIRE SPRINKLERS: Automatic fire sprinklers shall be installed in all occupancies in <br />accordance with the 2022 Pleasanton Building, Fire and Residential Codes with local <br />amendments and ordinances. <br />68. FIRE PROTECTION FACILITIES: Prior to any construction framing, the applicant shall <br />provide adequate fire protection facilities, including, but not limited to a water supply and <br />water flow in conformance to the City's Fire Department Standards able to suppress a major <br />fire. <br />69. WATER FLOW AND CONTROL VALVES: All fire sprinkler system water flow and control <br />valves shall be complete and serviceable prior to final inspection. Prior to the occupancy of <br />a building having a fire alarm system, the Fire Department shall test and witness the <br />operation of the fire alarm system. <br />70. ELECTRICAL CONDUIT: Electrical conduit shall be provided to each fire protection system <br />control valve including all valve(s) at the water connections. The Livermore-Pleasanton Fire <br />Department requires electronic supervision of all valves for automatic sprinkler systems and <br />fire protection systems. <br />71. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than 300 feet in <br />industrial and commercial developments. Fire hydrants shall be installed at spacing not <br />greater than 400 feet in residential developments. <br />72. FIRE LANE MARKING: On-site access ways, turnarounds, and internal drives shall be <br />designated as fire lanes and identified as such by red curb striping and posted with signs at <br />locations approve by the Fire Department. Signs shall be according to State standards and <br />read “No Parking – Fire Lane” and must be shown on the plans. The red curb striping, sign <br />location(s), and sign language shall be included in the building permit submittal for review <br />and approval by the Livermore-Pleasanton Fire Department prior to building permit <br />issuance. <br />a. The following schedule for NO PARKING signs shall apply: <br />Width Requirements <br />36 feet or greater No requirements <br />Between 28 and 36 feet Post one side <br />Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />Cul-de-Sac Not permitted <br />73. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 inches <br />unobstructed vertical clearance, 20 feet of unobstructed width (26 feet where occupied <br />building floors exceed 30 feet height), and inside turning radius of 31 feet and outside <br />turning radius of 51 feet. Unobstructed shall mean a clear travel way, excluding parking <br />width, and designed for an emergency vehicle weight of 70,000 pounds under all weather <br />conditions. Unobstructed width shall not include the width of rolled curbs, sidewalks, or non- <br />drivable surfaces. All exterior portions of buildings must be within 200 feet of an access
The URL can be used to link to this page
Your browser does not support the video tag.