My WebLink
|
Help
|
About
|
Sign Out
Planning Commission Meeting Agenda Packet 04222026
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2026
>
04-22
>
Planning Commission Meeting Agenda Packet 04222026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2026 11:22:28 AM
Creation date
7/8/2026 11:15:26 AM
Metadata
Fields
Template:
CITY CLERK
DOCUMENT DATE
4/22/2026
DESTRUCT DATE
15Y
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
593
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
City of Pleasanton <br />Hidden Canyon Residences and Preserve Project Mitigation Monitoring and Reporting Program <br /> <br /> <br />FirstCarbon Solutions 21 <br />https://adecinnovations.sharepoint.com/sites/PublicationsSite/Shared Documents/Publications/Client (PN-JN)/2148/21480016/MMRP/21480016 Hidden Canyon Residences and Preserve Project MMRP.docx <br />Mitigation Measures <br />Method of <br />Verification Timing of Verification <br />Responsible for <br />Verification <br />Verification of Completion <br />Date Initial <br />review and evaluate any discoveries to determine whether they are <br />historical resource(s) and/or unique archaeological resources under <br />CEQA. <br />If any prehistoric or historic artifacts, or other indication of cultural <br />resources are found once the project construction is underway, all <br />work shall stop within 20 meters (66 feet) of the find. A qualified <br />Archaeologist shall be consulted for an immediate evaluation of the <br />find prior to resuming groundbreaking construction activities within <br />20 meters of the find. If the find is determined to be an important <br />archaeological resource, the resource shall be either avoided, if <br />feasible, or recovered consistent with the requirements of the <br />California Environmental Quality Act (CEQA) Guidelines. <br />confirm inclusion of <br />a note indicating <br />the potential to <br />encounter buried <br />cultural resources, <br />Retention of a <br />qualified <br />Professional <br />Archaeologist who <br />shall review and <br />evaluate any <br />discoveries and field <br />verification and <br />incident <br />documentation. <br />3.6 Geology, Soils, and Seismicity <br />MM GEO-1: Design-level Geotechnical Study <br />Prior to the issuance of any building or grading permits, a design- <br />level geotechnical investigation on the project site and review of <br />detailed site plans shall be performed by a qualified Geotechnical <br />Engineer. The design level geotechnical investigation could <br />incorporate a variety of field methods and would include (but not be <br />limited to) the following items: <br />xx Evaluating the lateral extent and depth of colluvial soils. <br />xx Performing a seismic refraction survey to determine shear wave <br />velocities at deeper depths. <br />xx Analyzing and developing slope grading and engineered buttress <br />fill design criteria. <br />xx Evaluating upslope sources of water. <br />xx Evaluating the Site Classification for Seismic Design. <br />xx Estimating appropriate minimum building setbacks from the face <br />of fill slopes <br /> <br />Review of <br />documentation <br />prepared by a <br />qualified <br />Geotechnical <br />Engineer, agency <br />review by the City <br />Engineer <br />Prior to issuance of <br />any grading or <br />building permits. <br />City of Pleasanton <br />Community <br />Development <br />Department Planning <br />Division <br />
The URL can be used to link to this page
Your browser does not support the video tag.