My WebLink
|
Help
|
About
|
Sign Out
Planning Commission Meeting Supplemental Materials 04222026
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2026
>
04-22
>
Planning Commission Meeting Supplemental Materials 04222026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2026 11:26:29 AM
Creation date
7/8/2026 11:26:08 AM
Metadata
Fields
Template:
CITY CLERK
DOCUMENT DATE
4/22/2026
DESTRUCT DATE
15Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DRA <br />F <br />T <br /> <br /> <br /> <br /> <br />P18-0078, P18-0080, P18-0081, PUD-130, and Tract 8569 PC-2026-09, April 22, 2026 <br /> <br />18 of 36 <br /> <br />52. STORM WATER ENERGY DISSIPATION. The drainage design relies on storm <br />discharges onto unprotected natural hillside slopes. To reduce erosion potential, the <br />storm drain system shall be designed to dissipate energy and reduce flow velocity to <br />less than 6 feet-per-second at the discharge end of all outfalls. (Address this condition <br />prior to improvement plan approval). <br /> <br />53. PRIVATE STORM DRAIN EASEMENTS. Private storm drain easements shall be <br />granted across the western portion of Lot 30 for the benefit of Lot 29 and Parcel C, and <br />across Lot 29 for the benefit of Parcel C. The easements shall assure that storm runoff <br />within Devany Creek can flow unobstructed across these properties to the Dublin <br />Canyon Road culvert. Maintenance of the creek shall be the obligation of each property <br />owner, unless this obligation is transferred to the homeowner’s association. (Address <br />this condition prior to subdivision map approval). <br /> <br />54. POTABLE WATER. The potable water distribution system within the subdivision shall <br />be designed in accordance with the Hydraulic Analysis prepared by Akel Engineering <br />Group dated June 2024, specifically “Alternative 3 – Moller 770 Connection”, although <br />Lots 29 and 30 shall be connected to the Dublin Canyon Pressure Zone. Said system <br />shall be publicly owned and maintained by the City. Appropriate Public Service <br />Easements shall be granted across roads and access pathways to allow maintenance <br />access to these facilities. (Address this condition prior to subdivision map approval). <br /> <br />The City’s Utility Division requires a water inter-tie on Dublin Canyon Road between the <br />Dublin Canyon Pressure Zone and the Moller 770 Pressure Zone so the subdivision <br />can be temporarily fed from the Dublin Canyon zone if service from the Moller zone <br />is interrupted. Final design and coordination of the inter-tie is subject to the Utility <br />Division review and comment during the permitting phase. (Address this condition prior <br />to plan approval). <br /> <br />55. DESIGN STANDARDS: All permanent connections to the City’s potable water network <br />shall conform to Pleasanton Municipal Code §14.04.050. Any required water pressure <br />and/or flow needed by the project developer beyond that available from the network at <br />the point-of-connection must be provided by the project developer as a private <br />improvement on the customer side of the meter or backflow prevention device. All <br />extensions or upgrades to the potable water network shall be designed to satisfy the <br />following minimum standards: <br /> <br />a. Minimum number of valves: <br />i. 3 at cross intersections <br />ii. 2 at “T” intersections <br />iii. 500 feet maximum spacing <br />iv. 1 valve at each fire hydrant lateral
The URL can be used to link to this page
Your browser does not support the video tag.