My WebLink
|
Help
|
About
|
Sign Out
Planning Commission Meeting Agenda Packet 05132026
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2026
>
05-13
>
Planning Commission Meeting Agenda Packet 05132026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2026 11:54:19 AM
Creation date
7/8/2026 11:49:55 AM
Metadata
Fields
Template:
CITY CLERK
DOCUMENT DATE
5/13/2026
DESTRUCT DATE
15Y
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
and from my balcony. I have that view through the side yards between the homes across the <br />street from me, at and Liberty Drive. The right side of my view is currently limited <br />by the existing south wall and roof line of the home at 2986 Liberty Drive. The construction of <br />the proposed two story addition to the west side of that home will eliminate this view of the <br />ridgeline. <br />I want to call your attention to the following incorrect or missing information in the box <br />labeled "Project Data," in the upper right corner of Sheet A-1 (as received by the Planning <br />Division on 2/23/26): <br />1. The "Code Data" in this box currently includes the statement, "Fire Sprinklers: No." <br />However, it appears that Pleasanton Municipal Code Section 20.24.160 903.2 3.a will <br />require the installation of fire sprinklers in both the existing residence and proposed <br />addition. That is because the modification will result in a 50 percent or greater increase <br />to the original approved floor area of the existing residence. (Using the areas provided <br />by the architect in the "Project Data" box, an 816 square feet addition to the existing <br />1,400 square feet is a 58 percent increase.) <br /> <br />2. The "Applicable Codes" information cites the 2022 editions of the California Codes. <br />Much of this information is incorrect. Pleasanton Ordinance Number 2299, which <br />adopted later versions of (and amended) many of the codes, is dated 10/21/25. It <br />became effective on 1/1/26 (before the 2/23/26 date the Planning Division received the <br />drawings). <br /> <br />3. The "Code Data" does not indicate that the project is located in a High Fire Hazard <br />Severity Zone (Pleasanton Ordinance Number 2293). The "Applicable Codes" listed also <br />do not include the related Wildland-Urban Interface Code, also adopted by Pleasanton <br />Ordinance Number 2299. <br /> <br />There is no equivalent to the fire safety that fire sprinklers provide the occupants of a home. <br />However, it can be very expensive to install fire sprinklers. This is especially true when existing <br />walls or ceilings need to be opened if the owner wants concealed piping to fire sprinklers in <br />rooms with ceilings on the lower floor (such as the dining room and kitchen). If the staff of the <br />water utility or fire department require a larger water lead-in and/or water meter to supply <br />the fire sprinklers, those items can also significantly add to the project cost. In addition, a <br />larger water meter might more than double the amount of the bi-monthly water service <br />charge for the life of the home.
The URL can be used to link to this page
Your browser does not support the video tag.