Laserfiche WebLink
transmission pipeline, Contractor shall pay for construction of <br /> modifications to the transmission pipeline, including insertion of a new <br /> tee or other connection and associated in-line valves and the isolation <br /> valve on the tee, serving the turnout facility, in addition to any other <br /> costs described in Section 15. <br /> 18. Operations and Damage to Facilities <br /> Each Party shall exercise reasonable care in the performance of its obligations and <br /> rights under this Agreement to ensure that each Party's facilities and operations are not <br /> impaired or damaged. In the event that Contractor, by carrying out its obligations under <br /> this Agreement or in any other course of its operations damages Zone 7 facilities or <br /> structures, including but not limited to turnouts installed under this Agreement, the <br /> Contractor shall reimburse Zone 7 for costs of repairing those facilities. <br /> 19. Inspection of Facilities <br /> Contractor may, upon request, and in the presence of a Zone 7 representative, inspect <br /> its associated turnout facilities. Upon Contractor's request, Zone 7 shall provide Zone 7's <br /> monthly flow measurements and records taken from that Contractor's turnout facilities. <br /> 20. Ranges of Flow <br /> The range of flow rates of water through a turnout facility may vary considerably over <br /> the contract term. A normal range of flow rates for a turnout facility is hereby <br /> established as from 10% to 100% of the maximum approved design flow rate. <br /> Prior to the turnout design, Contractor shall provide Zone 7 with the anticipated <br /> ultimate (future) maximum flow rate and anticipated present design range of flow rates, <br /> as well as anticipated pressure ranges for each on Contractor's side of the turnout <br /> facility. The maximum design flow rate shall not exceed 10 times the minimum design <br /> flow rate for this range in normal installations as approved by Zone 7. <br /> Contractor is responsible for regulating flow demands through the turnout facility such <br /> that the range of flow rates set forth in the turnout design criteria will be maintained. <br /> Zone 7 may at its sole discretion elect to regulate flows. <br /> Zone 7 may modify turnout facilities upon request of Contractor or at such time that the <br /> actual flow rate exceeds the maximum design flow rate or is less than the minimum <br /> design flow rate; provided, however, that flow rates resulting from emergencies shall <br /> not apply to such requirement for modification. Said modification will be at the expense <br /> of the Contractor and payment thereof shall be invoiced to Contractor in accordance <br /> with Section 32. <br /> 10 <br />