Laserfiche WebLink
P18-0078, P18-0079, P18-0081, PUD-130, and Tract 8569 PC-2026-09, April 22, 2026 <br /> <br />90. VEGETATION MANAGEMENT COMPLIANCE: Shall be in accordance with the current <br />CBC chapter 7A (701A.5) and the 2022 CFC section 4906, including California Public <br />Resource Code Section 4291 or California Government Code Section 51182. <br /> <br />91. FIRE PROTECTION FACILITIES: Prior to any construction framing, the project <br />developer shall provide adequate fire protection facilities, including, but not limited to a <br />water supply and water flow in conformance to the City's Fire Department Standards <br />able to suppress a major fire. <br /> <br />92. HAZARDOUS MATERIALS: Should any operation or business activity involve the use, <br />storage or handling of hazardous materials, the project developer shall be responsible <br />for contacting the Livermore-Pleasanton Fire Department prior to commencing <br />operations. Please contact the Hazardous Materials Coordinator at 925-454-2361. <br /> <br />93. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than 300 feet <br />in industrial and commercial developments. Fire hydrants shall be installed at spacing <br />not greater than 400 feet in residential developments. <br /> <br />94. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives shall be <br />designated as fire lanes and identified as such by red curb striping and posted with <br />signs at locations approve by the Fire Department. Signs shall be according to State <br />standards and read “No Parking – Fire Lane” and must be shown on the plans. The red <br />curb striping, sign location(s), and sign language shall be included in the building permit <br />submittal for review and approval by the Livermore-Pleasanton Fire Department prior to <br />building permit issuance. <br /> <br />The following schedule for NO PARKING signs shall apply: <br /> <br />Width Requirements <br />36 feet or greater No requirements <br />Between 28 and 36 feet Post one side <br /> Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />Cul-de-Sac Not permitted <br /> <br />95. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 inches <br />unobstructed vertical clearance, 20 feet of unobstructed width (26 feet where occupied <br />building floors exceed 30 feet height), and inside turning radius of 31 feet and outside <br />turning radius of 51 feet. Unobstructed shall mean a clear travel way, excluding parking <br />width, and designed for an emergency vehicle weight of 70,000 pounds under all <br />weather conditions. Unobstructed width shall not include the width of rolled curbs, <br />sidewalks, or non-drivable surfaces. All exterior portions of buildings must be within 200 <br />feet of an access road. Yard and parking area may be able to be located farther than <br />200 feet from access roads, depending on the specific use. <br /> <br />    <br />  <br /> <br />