Laserfiche WebLink
PC-2026-16 June 24, 2026 <br />124. SITE SAFETY: Site safety during construction shall be in accordance with Fire <br />Code chapter 33. <br /> <br />125. FIRE SPRINKLERS: Automatic fire sprinklers shall be installed in all occupancies <br />in accordance with the 2025 Pleasanton Building, Fire and Residential Codes <br />with local amendments and ordinances. <br /> <br />126. FIRE PROTECTION FACILITIES: Prior to any construction framing, the <br />Applicant shall provide adequate fire protection facilities, including, but not limited <br />to a water supply and water flow in conformance to the City's Fire Department <br />Standards able to suppress a major fire. <br /> <br />127. HAZARDOUS MATERIALS: Should any operation or business activity involve <br />the use, storage or handling of hazardous materials, the firm shall be responsible <br />for contacting the Livermore-Pleasanton Fire Department prior to commencing <br />operations. Please contact the Hazardous Materials Coordinator at 925-454- <br />2361. <br /> <br />128. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than <br />300 feet in industrial and commercial developments. Fire hydrants shall be <br />installed at spacing not greater than 400 feet in residential developments. <br /> <br />129. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives <br />shall be designated as fire lanes and identified as such by red curb striping and <br />posted with signs at locations approve by the Fire Department. Signs shall be <br />according to State standards and read “No Parking – Fire Lane” and must be <br />shown on the plans. The red curb striping, sign location(s), and sign language <br />shall be included in the building permit submittal for review and approval by the <br />Livermore-Pleasanton Fire Department prior to building permit issuance. <br />a. The following schedule for NO PARKING signs shall apply: <br /> <br />Width Requirements <br />36 feet or greater No requirements <br /> <br />Between 28 and 36 feet Post one side <br />Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />Cul-de-Sac Not permitted <br />130. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 <br />inches unobstructed vertical clearance, 20 feet of unobstructed width (26 feet <br />where occupied building floors exceed 30 feet height), and inside turning radius <br />of 31 feet and outside turning radius of 51 feet. Unobstructed shall mean a clear <br />        <br /><br /><br /><br />