My WebLink
|
Help
|
About
|
Sign Out
CITY COUNCIL SPECIAL MEETING AGENDA PACKET 8-11-26
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2026
>
081126 SPECIAL
>
CITY COUNCIL SPECIAL MEETING AGENDA PACKET 8-11-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2026 9:09:20 AM
Creation date
8/7/2026 8:56:02 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
8/11/2026
DESTRUCT DATE
15Y
DOCUMENT NAME
SPECIAL MEETING AGENDA PACKET
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UP <br />WH WH <br />PARTITION RATING WALL ASSEMBLY LEGEND <br />XX.X <br />SEE SHEET A800 FOR <br />ASSEMBLY DETAILS <br />PROPOSED <br />NON-RATED TYPE-V WALL <br />PARTIAL HEIGHT <br />NON-RATED TYPE-V WALL <br />PROPOSED 1-HOUR RATED <br />TYPE-V WALL <br />WALL TYPE <br />STRUCTURAL MEMBER SIZE <br />1. DRAWINGS ARE ONLY REPRESENTATIVE OF CRITICAL DIMENSIONS, LAYOUT AND <br />CLEARANCES. ALL FINISHES, MATERIALS, DETAILS TO BE VERIFIED DURING CONSTRUCTION <br />WITH OWNER. <br />2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS <br />BEFORE PROCEEDING WITH THE WORK. <br />3. DO NOT SCALE DRAWINGS. <br />4. ALL DIMENSIONS ARE TO THE FACE OF STUDS, FACE OF CONCRETE OR MASONRY, AND <br />CENTERLINE OF, UNLESS NOTED OTHERWISE. ALL DIMENSIONS NOTED AS "CLEAR" SHALL <br />BE TO FACE OF FINISH. <br />5. REFERENCE TO ANY DETAIL OR DRAWING IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT <br />THE APPLICATION OF SUCH DETAIL OR DRAWINGS. <br />6. REFER TO STRUCTURAL FOR WALL FRAMING INFORMATION, U.N.O. <br />7. 6”EXTERIOR WALLS SHALL HAVE R-19 INSULATION (4”WALLS SHALL HAVE R-13). ROOFS <br />SHALL HAVE R-30 INSULATION, VERIFY WITH TITLE 24 REPORT. <br />8. OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILS, OR AN ORNAMENTAL PATTERN SUCH <br />THAT A SPHERE 4”IN DIAMETER CANNOT PASS THROUGH. <br />9. EXTERIOR GLAZING: EXTERIOR WINDOWS, WINDOW WALLS AND GLAZED DOORS, WINDOWS <br />WITHIN EXTERIOR DOORS, AND SKYLIGHTS SHALL BE TEMPERED GLASS, MULTI LAYERED <br />GLAZED PANELS, GLASS BLOCK OR HAVE A FIRE-PROTECTION RATING OF NOT LESS THAN 20 <br />MINUTES. <br />10. EXTEROR DOORS: EXTERIOR DOORS SHALL BE APPROVED NON-COMBUSTIBLE <br />CONSTRUCTION, SOLID CORE WOOD NOT LESS THAN 1-3/4”THICK, OR HAVE A FIRE <br />PROTECTION RATING OF NOT LESS THAN 20 MINUTES. WINDOWS WITHIN DOORS AND GLAZED <br />DOORS SHALL ALSO HAVE A FIRE-PROTECTION RATING OF NOT LESS THAN 20 MINUTES. <br />11. HANDRAILS SHALL COMPLY WITH THE FOLLOWING: <br />a. TOP OF HANDRAIL SHALL BE PLACED BETWEEN 34”& 38”ABOVE LANDINGS AND THE <br />NOSING OF THE TREAD. <br />b. HANDGRIP SHALL NOT BE LESS THAN 1-1/4”NOR MORE THAN 2”IN CROSS-SECTIONAL <br />DIMENSION WITH NO SHARP CORNERS. <br />c. HANDRAILS PROJECTING FROM THE WALL SHALL NOT HAVE LESS THAN 1-1/2”BETWEEN <br />WALL AND THE HANDRAIL. <br />12. DRYER VENT SHALL BE VENTED TO THE OUTSIDE AND SHALL NOT EXCEED 14’DISTANCE <br />WITH MAX (2) 90° ELBOWS. EACH ADDITIONAL ELBOW SHALL REDUCE THE MAX LENGTH BY <br />2’. <br />13. SHOWERS AND SHOWER/TUB SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF <br />THE PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION PRESSURE <br />BALANCE/THERMOSTATIC MIXING VALVE TYPE THAT PROVIDE SCALD AND THERMAL SHOCK <br />PROTECTION. <br />A301 <br />A301 <br />A300 <br />A300 <br />2 <br />1 <br />1 <br />2 <br />241 SF <br />123 <br />UTILITY <br />624 SF <br />124 <br />GARAGE <br />73 SF <br />106 <br />MEMETOS + <br />STORAGE <br />58 SF <br />104 <br />BATH <br />774 SF <br />105 <br />MANDIR <br />115 SF <br />112 <br />PANTRY <br />543 SF <br />111 <br />KITCHEN <br />432 SF <br />108 <br />DINING <br />1077 SF <br />107 <br />LIVING <br />113 <br />CORRIDOR <br />97 SF <br />116 <br />BATH <br />98 SF <br />118 <br />BATH <br />98 SF <br />120 <br />BATH <br />5' <br /> <br />- <br /> <br />9 <br />" <br />121 <br />HALLWAY <br />249 SF <br />122 <br />LOBBY <br />ELEV. <br />COVERED PATIO <br />15 <br />' <br /> <br />- <br /> <br />2 <br />" <br />1' <br /> <br />- <br /> <br />7 <br />" <br />1' <br /> <br />- <br /> <br />7 <br />" <br />15 <br />' <br /> <br />- <br /> <br />2 <br />" <br />1' <br /> <br />- <br /> <br />7 <br />" <br />15 <br />' <br /> <br />- <br /> <br />2 <br />" <br />16 <br />' <br /> <br />- <br /> <br />3 <br />" <br />22 <br />' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />29' - 10" <br />17 <br />' <br /> <br />- <br /> <br />2 <br />" <br />54 <br />' <br /> <br />- <br /> <br />2 <br />" <br />23' - 2" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />24 <br />' <br /> <br />- <br /> <br />7 <br />" <br />8' <br /> <br />- <br /> <br />8 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />31' - 8 1/2" <br />12' - 10" <br />40 <br />' <br /> <br />- <br /> <br />7 <br />" <br />5 <br />' <br /> <br />- <br /> <br />5 <br />" <br />5 <br />3 <br />' <br /> <br />- <br /> <br />2 <br />" <br />4' - 5" <br />14' - 10" <br />4' - 0 1/2" <br />10' - 0"12' - 9" <br />10 <br />' <br /> <br />- <br /> <br />9 <br />" <br />10 <br />' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />5' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />10 <br />' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />9' - 5" <br />4' <br /> <br />- <br /> <br />9 <br />" <br />5' <br /> <br />- <br /> <br />8 <br />" <br />5' - 9 1/2"2' - 9 1/2" <br />5' - 0"11' - 9" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />13 <br />' <br /> <br />- <br /> <br />7 <br />" <br />4' - 0"6' - 0" <br />4' <br /> <br />- <br /> <br />3 <br />" <br /> <br />1 <br />1 <br />' <br /> <br />- <br /> <br />1 <br />1 <br />" <br /> <br />4 <br />' <br /> <br />- <br /> <br />3 <br />" <br />4' - 0" <br />CLOSET <br />CLOSET <br />CLOSET <br />FI <br />R <br />E <br />P <br />L <br />A <br />C <br />E <br />96' - 3 1/2" <br />30' - 10" <br />99 <br />' <br /> <br />- <br /> <br />2 <br />" <br />5' - 0" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />3' - 6" <br />30 SF <br />126 <br />POWDER <br />172 SF <br />125 <br />MUD ROOM <br />COVERED <br />WALK <br />29 <br />' <br /> <br />- <br /> <br />6 <br />" <br />20 <br />' <br /> <br />- <br /> <br />0 <br />" <br />8" <br />1' - 6" <br />SITTING AREA 6' <br /> <br />- <br /> <br />5 <br />" <br />29 <br />' <br /> <br />- <br /> <br />6 <br />" <br />STORAGE <br />5' <br /> <br />- <br /> <br />6 <br />" <br />3' - 6" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />327 SF <br />103 <br />LIBRARY <br />3' <br /> <br />- <br /> <br />0 <br />" <br />SEE LANDSCAPE PLANS <br />FOR YARD DESIGN <br />SEE LANDSCAPE PLANS <br />FOR YARD DESIGN <br />SEE LANDSCAPE PLANS <br />FOR YARD DESIGN <br />100' - 8" <br />430 SF <br />UNIT A <br />430 SF <br />UNIT B <br />430 SF <br />UNIT C <br />11' - 0" X 11' -6 1/2" <br />C102 <br />OFFICE <br />UNIT D <br />20' - 0" <br />4' - 5"3' - 9 1/2" <br />3' - 2" <br />11' -6 1/2" X 18' -5" <br />130 <br />FAMILY ROOM <br />60 <br />' <br /> <br />- <br /> <br />7 <br />" <br />25' - 1" 30' - 9 1/2" 25' - 3 1/2" 19' - 6 1/2" <br />VAN <br />8' - 0" 9' - 0" <br />18 <br />' <br /> <br />- <br /> <br />0 <br />" <br />LEVEL EVCS4 <br />CHARGING STATION <br />LEVEL 2 <br />EV READY STALL <br />CARPOOL <br />LOCKERS <br />1 LONG-TERM <br />BICYCLE PARKING <br />AT-LEAST ONE BATHROOM AT THE ENTRY LEVEL SHALL BE PROVIDED WITH AGIN-IN-PLACE / <br />FALL PREVENTION REINFORCEMENT PER THE FOLLOWING: <br />1. SOLID LUMBER REINFORCEMENT <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 X 8 NOMINAL LUMBER. <br />3. REINFORCEMENT SHALL BE LOCATED BETWEEN 32" AND 39-1/4" ABOVE THE FINISHED <br />FLOOR, FLUSH WITH THE WALL FRAMING. <br />4. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE <br />FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />5. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />6. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS <br />ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL <br />REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE <br />LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. <br />ELECTRICAL PANEL <br />ELECTRICAL METER <br />GAS METER <br />WATER HEATERWH <br />ADA PATH OF TRAVEL <br />02 - 28 - 2025 <br />Sheet: <br />PROJECT NO <br />DRAWING DATA: <br />ISSUE DATE <br />SCALE <br />DRAWN BY <br />SHEET SIZE <br />IF SHEET IS LESS THAN SIZE INDICATED ABOVE, THIS IS A REDUCED <br />PRINT. REDUCE SCALE ACCORDINGLY. <br />24" x 36" <br />THIS DRAWING IS THE PROPERTY OF sda AND IS NOT TO BE <br />REPRODUCED IN WHOLE OR IN PART. IT IS TO BE USED FOR THE <br />PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT <br />TO BE USED ON ANY OTHER PROJECT. THIS DRAWING IS TO BE <br />RETURNED UPON THE WRITTEN REQUEST OF sda. <br />© COPYRIGHT 2023 SAJNI DESIGN & ARCHITECTURE <br />ALL RIGHTS RESERVED. <br />STAMP: <br />REVISION: <br />PROJECT: <br />CLIENT: <br />4195 CHINO HILLS PKWY, SUITE 599 <br />CHINO HILLS, CA 91709 <br />CONTACT: KEYUR MARU <br />714.390.0525 <br />KMARU@SAJNIDESIGN.COM <br />GAUTAM PATEL <br />5776 STONERIDGE MALL ROAD, STE 155 <br />PLEASANTON, CA 94588 <br />TEL: 559.789.3250 <br />EMAIL: GAUTAM.PATEL@AMRUT.US <br />As indicated <br />A200 <br />BERNAL <br />MULTI-FAMILY <br />231 OLD BERNAL AVE, <br />PLEASANTON, CA 94566 <br />24-008 <br />09.19.2024 <br />FIRST LEVEL <br />FLOOR PLAN <br />Author <br />WALL LEGEND <br />KEYNOTE LEGEND <br />KEY VALUE KEYNOTE TEXT <br />GENERAL NOTES FLOOR PLANSCALE: <br />3/16" = 1'-0"FIRST FLOOR FINISH LEVEL 1 <br />AGING-IN-PLACE NOTES <br />0'4'8' <br />3/16" = 1' <br />MARK DESCRIPTION DATE <br />FLOOR PLAN SYMBOL LEGEND <br />Page 281 of 373
The URL can be used to link to this page
Your browser does not support the video tag.