Laserfiche WebLink
1. DRAWINGS ARE ONLY REPRESENTATIVE OF CRITICAL DIMENSIONS, LAYOUT AND <br />CLEARANCES. ALL FINISHES, MATERIALS, DETAILS TO BE VERIFIED DURING CONSTRUCTION <br />WITH OWNER. <br />2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS <br />BEFORE PROCEEDING WITH THE WORK. <br />3. DO NOT SCALE DRAWINGS. <br />4.ALL DIMENSIONS ARE TO THE FACE OF STUDS, FACE OF CONCRETE OR MASONRY, AND <br />CENTERLINE OF, UNLESS NOTED OTHERWISE. ALL DIMENSIONS NOTED AS "CLEAR" SHALL BE <br />TO FACE OF FINISH. <br />5.REFERENCE TO ANY DETAIL OR DRAWING IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT <br />THE APPLICATION OF SUCH DETAIL OR DRAWINGS. <br />6.REFER TO STRUCTURAL FOR WALL FRAMING INFORMATION, U.N.O. <br />7.GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF <br />LEAVES AND DEBRIS. <br />8.UNDERSIDES OF EAVES SHALL BE PROTECTED IGNITION-RESISTANT MATERIALS OR NON- <br />COMBUSTIBLE CONSTRUCTION. <br />PARTITION RATING WALL ASSEMBLY LEGEND <br />XX.X <br />SEE SHEET A800 FOR <br />ASSEMBLY DETAILS <br />PROPOSED <br />NON-RATED TYPE-V WALL <br />PARTIAL HEIGHT <br />NON-RATED TYPE-V WALL <br />PROPOSED 1-HOUR RATED <br />TYPE-V WALL <br />WALL TYPE <br />STRUCTURAL MEMBER SIZE <br />A301 <br />A301 <br />A300 <br />A300 <br />2 <br />1 <br />1 <br />2 <br />4" / 12"4" / 12" <br />4" / 12"4" / 12" <br />4" / 12"4" / 12" <br />4" / 12"4" / 12" <br />4" / 12" <br />4" / 12"VALLEYVALLEYVALLEYRI <br />D <br />G <br />E <br />VALLEY <br />V A L L E Y <br />RIDGE <br />RI <br />D <br />G <br />E <br />FLAT ROOF <br />FLAT ROOF <br />FLAT ROOF <br />1/4 : 12 <br />FLAT ROOF <br />1/4 : 12 <br />FLAT ROOF <br />1/4 : 12 <br />1/ <br />4 <br /> <br />: <br /> <br />1 <br />2 <br />1/ <br />4 <br /> <br />: <br /> <br />1 <br />2 <br />16' - 5"16' - 5" <br />32' - 10" <br />8' - 0" <br />46 <br />' <br /> <br />- <br /> <br />0 <br />" <br />13' - 10" 13' - 9" <br />27' - 7" <br />55 <br />' <br /> <br />- <br /> <br />2 <br />" <br />13' - 9 1/2" 13' - 9 1/2" <br />27' - 7" <br />20' - 6 1/2"13' - 7 1/2"13' - 7 1/2" <br />27' - 3" <br />18 <br />' <br /> <br />- <br /> <br />8 <br />" <br />13' - 0"13' - 0" <br />26' - 0" <br />38 <br />' <br /> <br />- <br /> <br />6 <br />" <br />1' - 0" <br />2' - 0" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" <br />1' - 0" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" <br />1' - 0" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' - 0" <br />PROPOSED SOLAR <br />PANEL LOCATION <br />PROPOSED SOLAR <br />PANEL LOCATION <br />PROPOSED SOLAR <br />PANEL LOCATION <br />PROPOSED SOLAR <br />PANEL LOCATION <br />PROPOSED SOLAR <br />PANEL LOCATION <br />PROPOSED SOLAR <br />PANEL LOCATION <br />PROPOSED SOLAR <br />PANEL LOCATION <br />I <br />I <br />I <br />I <br />11' - 0" <br />4" / 12"4" / 12" <br />I <br />J <br />J <br />J <br />J <br />J <br />02 - 28 - 2025 <br />Sheet: <br />PROJECT NO <br />DRAWING DATA: <br />ISSUE DATE <br />SCALE <br />DRAWN BY <br />SHEET SIZE <br />IF SHEET IS LESS THAN SIZE INDICATED ABOVE, THIS IS A REDUCED <br />PRINT. REDUCE SCALE ACCORDINGLY. <br />24" x 36" <br />THIS DRAWING IS THE PROPERTY OF sda AND IS NOT TO BE <br />REPRODUCED IN WHOLE OR IN PART. IT IS TO BE USED FOR THE <br />PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND IS NOT <br />TO BE USED ON ANY OTHER PROJECT. THIS DRAWING IS TO BE <br />RETURNED UPON THE WRITTEN REQUEST OF sda. <br />© COPYRIGHT 2023 SAJNI DESIGN & ARCHITECTURE <br />ALL RIGHTS RESERVED. <br />STAMP: <br />REVISION: <br />PROJECT: <br />CLIENT: <br />4195 CHINO HILLS PKWY, SUITE 599 <br />CHINO HILLS, CA 91709 <br />CONTACT: KEYUR MARU <br />714.390.0525 <br />KMARU@SAJNIDESIGN.COM <br />GAUTAM PATEL <br />5776 STONERIDGE MALL ROAD, STE 155 <br />PLEASANTON, CA 94588 <br />TEL: 559.789.3250 <br />EMAIL: GAUTAM.PATEL@AMRUT.US <br />As indicated <br />A203 <br />BERNAL <br />MULTI-FAMILY <br />231 OLD BERNAL AVE, <br />PLEASANTON, CA 94566 <br />24-008 <br />09.19.2024 <br />ROOF PLAN <br />Author <br />GENERAL NOTES ROOF PLAN <br />WALL LEGEND <br />KEYNOTE LEGEND <br />KEY VALUE KEYNOTE TEXT <br />I STANDING SEAM METAL ROOF, CLASS A FIRE RATED, METAL SALES VERTICAL <br />SEAM, ESR #2385, SEE SPECS A500, BLACK FASCIA COLOR TO MATCH ROOF <br />FINISH <br />J 60 MIL. CLASS A TPO ROOFING MEMBRANE MECHANICALLY FASTENED PER <br />MANUFACTURER REQUIREMENTS WITH VERASHIELD FIRE-RESISTANT SLIP <br />SHEET OVER SLOPED RIGID INSULATION , PROVIDE FLASHING STRIP, SEE SPECS <br />ON A500 <br />SCALE: <br />3/16" = 1'-0"TOP OF ROOF LEVEL 1 <br />0'4'8' <br />3/16" = 1' <br />MARK DESCRIPTION DATE <br />Page 284 of 373