Laserfiche WebLink
WH WHWHWH <br />M FS <br />BF <br />P <br />Q.C. <br />Q.C. <br />A-9 <br />1"8.5 <br />A-10 <br />1"6.1 <br />A-6 <br />4.13/4" <br />A-7 <br />3/4"1.0 <br />Q.C. <br />A-8 <br />3/4"0.8 <br />A-1 <br />3/4"3.0 <br />A-2 <br />3/4"4.8 <br />A-3 <br />3/4"2.0 <br />Q.C. <br />A-4 <br />3/4"4.0 <br />A-5 <br />1"4.8 <br />1" PRESSURE MAINLINE <br />NEW 1" SUB WATER METER <br />FOR IRRI. USE ONLY <br />TO WATER METER <br />P.V.C. SLEEVE TYP. <br />P.V.C. SLEEVE TYP. <br />A <br />S <br />WEATHER-BASED AUTOMATIC <br />RAIN SENSOR <br />IRRIGATION CONTROLLER <br />1" <br />1" <br />1" <br />1" <br />3/4" <br />3/4" <br />3/4" <br />3/4" <br />3/4" <br />3/4"3/4" <br />3/4" <br />3/4" <br />3/4" <br />3/4" <br />1 1/4" PRESSURE MAINLINE - SCH. 40 IPS PVC (SIZE PER PLAN) <br />NON-PRESSURE LATERAL - SCH. 40 IPS PVC (SIZE PER PLAN) <br />P.V.C. SLEEVE (UNDER IN PAVING), SCH. 40 P.V.C. 2X DIA. OF PIPE. <br />INSTALL SLEEVE UNDER ALL PAVEMENT. (PER PLAN) <br />PLACE WIRES IN MAINLINE SLEEVE <br />IRRIGATION LEGEND <br />RAINBIRD XCZ-075-PRF <br />RAINBIRD LANDSCAPE DRIP XF SERIES XFS-06-18 (SUB SURFACE) <br />LOW FLOW CONTROL ZONE KITS W/ PR FILTER <br />W/ P.V.C. SLEEVE UNDER IN PAVING <br />BFP REDUCED PRESSURE BACKFLOW FEBCO 825-Y 1 1/2" W/ <br />MANUAL SHUT OFF VALVE 1" BALL VALVE BRASS NIBCO T-580 A <br />ROOT ZONE WATERING SYSTEM RAINBIRD RWS-B-C-1402 (0.5 GPM) <br />FLOW SENSOR RAIN BIRD FS100B 1 1/2" BRASS TEE FLOW SENSORFS <br />MASTER VALVE RAIN BIRD 1 1/2" BRASS VALVE EFB-CP SERIESM <br />SUB LANDSCAPE WATER METERS FM150B 1 1/2" <br />1 1/4" BRONZE WATER PRESSURE REGULATOR ZURN WILKINS 1-500XL <br />Q.C.QUICK COUPLER VALVE - RAINBIRD 33 DRC--3/4" <br />G.P.M. <br />A-1 <br />VALVE SIZE <br />VALVE SEQUENCE <br />S <br />3(PER LAMC. 4.304.1) <br />RAINBIRD - RAIN SHUT OFF RSD SERIES <br />101" <br />WEATHER-BASED AUTOMATIC IRRIGATION CONTROLLER <br />RAINBIRD ESP-ME3 4 TO 22 STATIONS <br />INSTALL IN-DOOR / OUT -DOOR CABINET (PER LAMC. 4.304.1) <br />A <br />RAINBIRD XCZ-100-PRF <br />MEDIUM FLOW CONTROL ZONE KITS W/ PR FILTER <br />BACKFILL TO PREVENT ARCHINGOR SLIPPING OF PIPE. ALL JOINTS SHALL <br />OVER SPRAY ON TO WALKS, ROADS, AND/OR BUILDINGS INCLUDING SELECTING <br />4. PROVIDE MINIMUM 18" COVER FROM FINISH GRADE TO TOP OF PIPE, PRESSURE <br />VALVE BOXES SHALL BE A MINIMUM OF 12" APART. <br />3. VALVE BOXES SHALL BE LOCATED 12" FROM THE EDGE OF CURB, WALKWAYS AND <br />BROUGHT IT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. <br />THE FIELD CONDITIONS ARE OBVIOUS, THAT OBSTRUCTIONS, GRADE DIFFERENCE <br />2. DO NOT INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN <br /> WIRE CONNECTORS IN VALVE BOXES ONLY. <br />FOR A MINIMUM OF 2 HOURS. CONTRACTOR MAY CENTER-LOAD PIPE WITH <br /> A: PRESSURE TEST MAINLINE UNDER HYDROSTATIC PRESSURE OF 150 PSI <br />10. IN THE PRESENCE OF THE OWNER'S REPRESENTATIVE: <br />9. TRENCHES SHALL BE COMPACTED AND/ OR JETTED TO PREVENT SETTLEMENT. <br />COMMON WIRES. ALL WIRE RUN TO FOLLOW MAINLINE. <br />8. ROUTE ONE EXTRA WIRE WITH A COLOR DIFFERENT THAN THE CONTROL AND <br />7. WIRE CONNECTIONS, ALL SPLICES SHALL BE MADE WITH PENTILE ON EQUAL <br />CENTER AND BURIED BENEATH THE MAINLINE. <br />6. CONTROL WIRES SHALL BE BUNDLED WITH ELECTRICAL TAPE AT 10 FT. ON <br />THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. <br />5. ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT <br />PIPE (MAINLINE), AND 12" COVER FOR NON PRESSURE PIPE, LATERAL LINE. <br /> AND AREA DIMENSIONS ARE NOT ACCURATE. SUCH DIFFERENCES SHALL BE <br />SHALL BE LOCATED IN PLANTING AREAS WHEREVER POSSIBLE. <br />1. IRRIGATION PLAN IS DIAGRAMATIC. ALL PIPING AND IRRIGATION IMPROVEMENTS <br />IRRIGATION NOTES <br />AND FAULTY PARTS FOR PERIOD OF 12 MONTHS. <br />11. CONTRACTOR SHALL GUARANTEE WORK AGAINST DEFECTIVE INSTALLATION <br />COVERAGE IS COMPLETEAND ADEQUATE. <br /> B: COVERAGE TEST, SHALL BE PERFORMED TO DETERMINE IF THE <br />REMAIN EXPOSED FOR INSPECTION. <br />CONSTRUCTION NOTES <br />1. WATER METER AND SERVICE LINE SHALL BE A MINIMUM SIZE OF 1". <br />2. CONTRACTOR SHALL CONFIRM WATER PRESSURE PRIOR TO INSTALLING THE <br /> IRRIGATION SYSTEM AND REQUEST PLAN CHANGE IF PRESSURE IS LOWER <br />THAN THE DESIGN RATING. <br />3.RIGID PIPE, COPPER TYPE "K" AND/OR BRONZE PIPE SHALL CONNECT THE BACK <br />FLOW TO THE SERVICE LINE. <br />4.CONTRACTOR SHALL CONTACT UNDERGROUND MODIFICATION SERVICE, "DIG <br />ALERT," PRIOR TO ANY UNDERGROUND ACTIVITY AND REQUEST DRAWINGS OF THE <br />EXISTING SITE UTILITIES. <br />5.OWNER SHALL PROVIDE AN 1" GATE VALVE AT THE EXISTING WATER SERVICE <br />FOR THE IRRIGATION MAINLINE POINT OF CONNECTION (P.O.C). <br />6.OWNER SHALL PROVIDE 120 VOLT ELECTRICAL POWER OUTLET AT THE <br />IRRIGATION CONTROLLER LOCATION, CONTRACTOR SHALL MAKE FINAL <br />ELECTRICAL CONNECTION TO THE CONTROLLER. <br />7.CONTRACTOR SHALL ADHERE TO ALL CAL OSHA REQUIREMENTS, AND <br />PROTECT THE PUBLIC FROM HIS CONSTRUCTION ACTIVITIES. <br />8. ALL WORK SHALL COMPLY WITH THE LATEST UNIFORM PLUMBING CODES AS <br />WELL AS LOCAL ORDINANCES. <br />9.CONTRACTOR SHALL PULL ALL WIRES THROUGH CONDUIT FROM STREET LEVEL <br />TO PODIUM LEVEL. <br />10.ALL CONDUITS SHALL BE COORDINATED WITH GENERAL CONTRACTOR. <br />11.SUBSLAB COPPER PIPES SHALL BE PROVIDED BY PLUMBING CONTRACTOR <br />W/ STUB - OUT AT PLANTERS. <br />12.ELECTRICAL CONDUITS FOR CONTROL WIRES TO CONTROLLERS SHALL BE <br />PROVIDED BY THE ELECTRICAL CONTRACTOR. <br />13.LANDSCAPE CONTRACTOR SHALL PULL WIRES THROUGH EXISTING CONDUIT <br />FROM CONTROLLER LOCATION TO EACH REMOTE CONTROL VALVE ABOVE SLAB. <br />14.CONTRACTOR SHALL COORDINATE ALL UNDER SLAB WORK WITH GENERAL <br />CONTRACTOR PRIOR TO COMMENCING ANY WORK <br />NOTE: <br />"AT THE TIME OF FINAL INSPECTION, THE PERMIT APPLICANT MUST PROVIDE THE OWNER OF THE PROPERTY WITH <br />CERTIFICATE OF COMPLETION, CERTIFICATE OF INSTALLATION, IRRIGATION SCHEDULE OF LANDSCAPE AND IRRIGATION <br />MAINTENANCE." <br />"UNLESS CONTRADICTED BY A SOIL TEST, COMPOST AT A RATE OF A MINIMUM OF FOUR CUBIC YARDS PER 1,000 <br />SQUARE FEET OF PERMEABLE AREA SHALL BE INCORPORATED TO A DEPTH OF SIX INCHES INTO THE SOIL." <br />"FOR SOILS LESS THAN 6% ORGANIC MATTER IN THE TOP 6" OF SOIL, COMPOST AT A RATE OF A MINIMUM OF FOUR <br />CUBIC YARDS PER 1,000 SQUARE FEET OF PERMEABLE AREA SHALL BE INCORPORATED TO A DEPTH OF SIX INCHES <br />INTO THE SOIL." <br />"A DIAGRAM OF THE IRRIGATION PLAN SHOWING HYDROZONES SHALL BE KEPT WITH THE IRRIGATION CONTROLLER <br />FOR SUBSEQUENT MANAGEMENT PURPOSES." <br />"A CERTIFICATE OF COMPLETION SHALL BE FILLED OUT AND CERTIFIED BY EITHER THE SIGNER OF THE LANDSCAPE <br />PLANS, OR THE LICENSED LANDSCAPE CONTRACTOR FOR THE PROJECT." <br />"AN IRRIGATION AUDIT REPORT SHALL BE COMPLETED AT THE TIME OF FINAL INSPECTION." <br />RECIRCULATING WATER SYSTEMS SHALL BE USED FOR WATER FEATURES. <br />A MINIMUM OF 3-INCH LAYER OF MULCH SHALL BE APPLIED ON ALL EXPOSED SOIL SURFACES OF PLANTING AREAS <br />EXCEPT TURF AREAS, CREEPING OR ROOTING GROUNDCOVERS, OR DIRECT SEEDING APPLICATIONS WHERE MULCH IS <br />CONTRAINDICATED. <br />PRESSURE REGULATING DEVICES ARE REQUIRED IF WATER PRESSURE IS BELOW OR EXCEED THE RECOMMENDED <br />PRESSURE OF THE SPECIFIED IRRIGATION DEVICES. <br />PA <br />T <br />E <br />L <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />ST <br />U <br />I <br />O <br /> <br />3 <br />1 <br />7 <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br />S <br />IR <br />R <br />I <br />G <br />A <br />T <br />I <br />O <br />N <br /> <br />P <br />L <br />A <br />N <br />LI-1 <br />4 <br />IRRIGATION PLAN <br />NOTE: PLAN IS SHOWN DIAGRAMATICALLY. <br />0 8'16'24' <br />Scale: 3/32" = 1'-0" <br />NORTH <br />Page 301 of 373