My WebLink
|
Help
|
About
|
Sign Out
CORE & MAIN LP (#2027021)
City of Pleasanton
>
CITY CLERK
>
CONTRACTS
>
C
>
CORE & MAIN LP (#2027021)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2026 3:47:47 PM
Creation date
8/21/2026 3:44:04 PM
Metadata
Fields
Template:
CONTRACTS
Description Type
Goods and Services
Contract Type
New
NAME
CORE & MAIN LP
Contract Record Series
704-05
Munis Contract #
2027021
Contract Expiration
6/30/2024
NOTES
WATER METER REPLACEMENT & AMI SYSTEM PROJECT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RFP-2 – Scope of Work <br />RFP# PWD 25.604 City of Pleasanton, CA RFP-2 | Page 15 <br />Internal Use Only <br />2.2.6.Radio Transmitter Mounting options <br />Nearly all the City’s meter box lids are RF-friendly Armorcast polymer concrete lids. Please see Appendix A of <br />this Scope of Work for meter box lid specifications. <br />The City’s preference is to maintain its existing meter box lids and not change them as part of this project. The <br />Contractor should plan to mount Radio transmitters below the existing meter box lids. If this is not possible for <br />RF propagation or incompatible mounting reasons, the Contractor should propose the appropriate lid <br />replacements or modifications to best suit the proposed AMI solution and meet the RSR requirements <br />established herein. All lid replacements or modifications must be included in WB-C Financial Workbook. The <br />City will accept AMI solutions where the radio transmitter is mounted integrally to the meter register provided it <br />meets the RSR established herein. <br />The Contractor’s radio transmitter mounting solution shall conform to the following: <br />No locking mechanism is allowed, the weight of the lid shall be sufficient to keep the lid in place <br />Any "through-the-lid" antenna shall be installed to comply with the Americans with Disabilities Act <br />(ADA) Accessibility Standards, Section 303 for vertical changes in level. Changes in level of 1/4 inch (6.4 <br />mm) high maximum shall be permitted to be vertical. Changes in level between 1/4 inch (6.4 mm) high <br />minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. <br />The submittal document for the proposed lid model(s) should include the coefficient of friction value, <br />confirmation of AASHTO H20 vertical loading, and the anti-slip rating. <br />The Radio Transmitter shall be secured to the lid to avoid damage to the device when removing the lid <br />If drilling an existing lid is proposed, the Contractor shall provide an engineering stamped confirmation <br />that the integrity of the lid will not be impacted. <br />All AMI Radio Transmitter mounting equipment shall be provided by the Contractor <br />2.2.7.Radio Transmitter Labelling <br />The Contractor shall ensure radio transmitters include a weatherproof label on the side of the device that <br />includes the name of the manufacturer, model, version, firmware references, the date of manufacture, the part <br />number, appropriate FCC certifications, and a unique Identification (ID) number that is both numeric and <br />barcoded (Code 39 or approved equivalent) that allows the ID number to be read by a digital work order system. <br />The label shall be able to remain attached to and readable in a submerged environment. <br />Where there is an outside cover, the Contractor shall ensure this information is included on the outside cover <br />and inside device itself. <br />2.2.8.Wire and Connectors <br />The Contractor shall ensure radio transmitters have 22-gauge 3-conductor solid wire potted lead with a wire <br />connector device installed at the time of manufacture. Between the AMI Radio Transmitters and the water <br />meter register there should be a minimum of 5 feet of wire to allow for the meter box lid to be removed. <br />The Contractor shall supply a wiring connector device that is a certified IP68 connection, tamper proof and can <br />be connected and disconnected without having to cut the wire or break the connector device. There shall be no <br />manual connections (e.g. gel caps) and there must be consistency among connectors across all meter brands. <br />Wiring connectors must be fully compatible with the Nicor Series III connectors present on existing Elster EvoQ4, <br />Kamstrup FlowIQ, and Sensus OMNI meters that will remain in the field as identified in 2.2.4, above. <br />Docusign Envelope ID: 6AD75F50-8A33-85A5-8039-9E3E1257A838Docusign Envelope ID: 177582DA-4F1C-8834-813C-BC4FD03AA45E
The URL can be used to link to this page
Your browser does not support the video tag.