Laserfiche WebLink
PC Resolution No. PC-2026-26 September 23, 2026 <br />refer to Pleasanton Municipal Code Title 14. (Address this condition prior to <br />building permit issuance) <br /> <br />68. BACKFLOW PREVENTION ASSEMBLIES: Backflow preventer assemblies shall <br />be designed and installed in accordance with current City Standard Drawings <br />704, 705, 706; Pleasanton Municipal Code Chapter 14.16, State Health and <br />Safety Code; State Water Resources Control Board adopted Cross-Connection <br />Control Policy Handbook (CCCPH); and as required by the Public Works <br />Department. Backflow Preventers (BFP) shall be selected from the latest “List of <br />Approved Backflow Prevention Assemblies” available from the Foundation for <br />Cross-Connection Control and Hydraulic Research at the University of Southern <br />California. All backflow preventer assemblies shall be tested and certified by a <br />City approved tester with the certification submitted to the City. Testing will be <br />performed at the time City water is turned on to the site. If an existing backflow <br />preventer is on the site, it shall be tested and certified by a City-approved tester <br />with the certification submitted to the City before project water is drawn through <br />it. An all-weather cover shall be placed over all backflow prevention assemblies <br />4 inches and smaller, and follow City Standard Specification 19-02N for backflow <br />enclosure requirements. (Address this condition prior to plan approval) <br /> <br />69. SINGLE-FAMILY RESIDENTIAL FIRE PROTECTION SYSTEMS AND <br />BACKFLOW PREVENTION: Single-family residential water services which <br />include a fire protection system must be equipped with either Double Check (DC) <br />valve backflow protection (requiring annual testing) or satisfy CCCPH section <br />3.2.2(e)(3) with pass-through/purge design of fire protection system with signage <br />posted at fixture to bring attention to the system design with pass-through/purge. <br />If applicant selects to install DC, assembly shall be designed and installed in <br />accordance with current City Standards 704, 705, and PMC 14.16; including <br />installation as close as possible to the service line before the first branch line <br />leading off the service line. (Address this condition prior to plan approval) <br /> <br />70. UTILITY ENCLOSURES: Proposed utility enclosures including vaults, meter <br />boxes, splice boxes, and pedestals shall be installed in the public right-of-way, in <br />a public service easement (PSE), or in a utility company specific easement. The <br />locations for utility enclosures shall be considered in the following order of <br />preference: (1) PSE area behind public sidewalk; (2) parkstrip area between the <br />roadway curb & gutter and the sidewalk; (3) within the public sidewalk set flush to <br />grade; (4) within driveway approach areas set flush to the surface with traffic- <br />rated lids. In no case shall an above-ground pedestal or utility cabinet obstruct <br />sight-line visibility for vehicle drivers at intersections or driveways. Above-ground <br />pedestals or utility cabinets are preferred within the side-yard area of a corner <br />residential lot rather than the front-yard. Deviations from this standard must be <br />approved by the City Engineer. (Address this condition prior to plan approval) <br /> <br />71. DRY UTILITIES (ELECTRICITY, CATV, TELECOM): All dry utilities including <br />electricity, telecommunications, cable television, street lights, alarm systems, etc. <br />Docusign Envelope ID: A549EA74-ED4F-8CB2-8262-A310230CC465