My WebLink
|
Help
|
About
|
Sign Out
SR 06:060
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2006
>
SR 06:060
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2007 4:06:08 PM
Creation date
2/15/2006 4:39:04 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
2/21/2006
DESTRUCT DATE
15 Y
DOCUMENT NO
SR 06:060
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
385
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />1readweI1&RoI1o <br /> <br />Mr. Jonathan Scharfman <br />Silver Stone Conununities <br />10 June 2005 <br />Page 5 <br /> <br />Historically, ground surface displacements closely follow the trace of geologically young faults. <br />The site is not within an Earthquake Fault Zone, as defined by the Alquist-Priolo Earthquake <br />Fault Zoning Act, and no known active or potentially active faults exist on the site. The nearest <br />known fault is an inactive extension ofthe Verona Fault which is about one kilometer south of <br />the site. In a seismically active area, the remote possibility exists for future faulting in areas <br />where no faults previously existed; however, we conclude the risJc of surface faulting and <br />consequent secondary ground failure is very low. We therefore conclude the risk offault offset <br />at the site from a known active fault is low. <br /> <br />If the buildings are designed in accordance with the 1997 Uniform Building Code (UBC), the <br />requirements for Zone 4 should be used as a minimwn. The site'is about 4.1 kilometers from the <br />Calaveras Fault (a B-type fault). The anticipated soil conditions at the site indicate the soil profile <br />type is an SD, with near-source factors of I .09 and 1.32 for N. and Nv, respectively. <br /> <br />Foundations <br /> <br />We anticipate that the buildings can be supported on shallow footings bearing on native soil. <br />The primary concern from a foundation standpoint is whether or not weak soil is present at the <br />site, its depth and extent. This can only be determined with on-site exploration. Weare <br />presenting herein our preliminary foundation recommendations for the condition where the soft <br />silt is absent, and where it is present. <br /> <br />If the soft surface layer of silt is absent, we conclude the proposed buildings can be supported on <br />conventional continuous and isolated footings that bear in undisturbed native soil or engineered <br />fill. We anticipate that allowable bearing pressures in the range of 2,000 to 3,000 pounds per <br />square foot (pst) will be appropriate. Footings would have minimwn widths of about 18 to <br />24 inches and minimwn depths of 18 inches. <br /> <br />If site exploration discovers soft soil similar to what was found on the adjacent sites, several <br />approaches can be taken to mitigate its effects, which would primarily be excessive settlement. <br />The weak soil could be removed and replaced as engineered fill if its depth is not too great. If <br />removal is impractical, some form of in-situ improvement could be undertaken. The use of <br />rammed aggregate piers (Geo Piers) has been used effectively in the Pleasanton area. Deep soil <br />compaction may also be viable. <br /> <br />Alternatively, a stiffened foundation system may be possible where soft soil is too thick to <br />remove and recompact, provided anticipated total and differential settlements can be tolerated. <br />Stiffened, shallow foundation systems appropriate for the site include grids (interconnected, <br />well-reinforced continuous footings) and post-tensioned slabs bearing on native soil or <br />engineered fill. <br />
The URL can be used to link to this page
Your browser does not support the video tag.