Laserfiche WebLink
<br />Geotechnical/Alquist-Priolo Earthquake Fault Zone <br /> <br />The Alquist-Priolo Earthquake Fault Zone for the Calaveras fault traverses the upper portion of <br />the Austin property near Lots 5 and 6. The site was analyzed by the applicants' consultant, Ber- <br />logar Geotechnical Consultants, with their findings peer-reviewed by Cotton, Shires and Associ- <br />ates under supervision by the City Engineer. The analyses determined that the site will support <br />the proposed development in its proposed configuration with standard engineering practices. As <br />shown on the development plan and grading/drainage plan, the geotechnical building setback <br />line encroaches onto the west sides of Lots 5 and 6. All habitable structures must be constructed <br />outside this setback line. Staff notes that the side yard building setback recommended by staff <br />in the "Design Guidelines" section of staff report is compatible with the geotechnical building <br />setback line. <br /> <br />The applicants are required to annex this development into the Lemoine Ranch Geologic Hazard <br />Abatement District (GRAD). In addition to the Lemoine development, GHADs cover the <br />Golden Eagle Estates, Kolb Ranch, Moller Ranch, Oak Hill Estates, Oak Tree Farms, and Pre- <br />serve developments. The project developer will be responsible for preparing the necessary <br />documentation to annex this development to the Lemoine Ranch GHAD including any expenses <br />of the City's geotechnical engineer for the GHAD. Upon recordation of the final subdivision <br />map, the lot owners will be responsible for paying the future annual GRAD assessments for the <br />development. <br /> <br />GradinglUrban Stormwater Runoff <br /> <br />Grading <br /> <br />The proposed grading plan - Figure 10 on Page 25 - was determined by several factors: <br /> <br />. To the greatest extent feasible, depress the entire development into the property by cut- <br />ting into the hillside in order to reduce its visibility to the Laguna Oaks development. <br />. Preserve the three swales/seeps, which flank and bisect the development. Staff notes that <br />these swales/seeps are subject to the Army Corps of Engineers and the Regional Water <br />Quality Control Board jurisdictions. <br />. Grading sensitive to the site's topography given its topographic complexities. <br />. Preserve the existing trees on the caretaker's property, which will become Lots 7 and 8. <br /> <br />The proposed grading plan incorporates the following features to meet these goals: <br /> <br />. All lots will be "cut" into the hillside. The depth of the cuts will vary from an average of <br />seven feet for Lots 1,3, and 5 up to an average of 11 feet for Lot 4 and Lot 6. <br />. A retaining wall will be used along the south side of the street, opposite Lots 2 and 3, in <br />order to preserve the swale/seep. <br />. Lot 4 will be graded with a four-foot split pad. <br /> <br />Item 6.c., PUD-58 and PGPA-II <br /> <br />Page 24 of 34 <br /> <br />August 23, 2006 <br />