Laserfiche WebLink
20.20.027 <br />disconnecting means of the other tified for such operation. <br />source(s) at any distribution equip- <br />ment on the premises, provided that VIII. Storage Batteries <br />all of the following conditions are <br />met: 690.71 Installation. <br />(1) Each source interconnection <br />shall be made at a dedicated circuit <br />breaker or fusible disconnecting <br />means. <br />(2) The sum of the ampere ratings <br />of over current devices in circuits <br />supplying power to a busbar or <br />conductor shall not exceed the rat- <br />ing of the busbar or conductor. <br />(A) General. Storage batteries in a <br />solar photovoltaic system shall be <br />installed in accordance with the <br />provisions of Article 480. The inter- <br />connected battery cells shall be con- <br />sidered grounded where the photo- <br />voltaic power source is installed in <br />accordance with 690.41. <br />(B) Dwellings. <br />Exception: For a dwelling unit, the (1) Operating Voltage. Storage bat- <br />sum of the ampere ratings of the teries for dwellings shall have the <br />over current devices shall not ex- cells connected so as to operate at <br />ceed 120 percent of the rating of less than 50 volts, nominal. <br />the busbar or conductor. <br />Exception: Where live parts are not <br />(3) The interconnection point shall accessible during routine battery <br />be on the line side of all ground- maintenance, a battery system volt- <br />fault protection equipment. age in accordance with 690.7 shall <br />be permitted. <br />Exception: Connection shall be <br />permitted to be made to the load (2) Guarding of Live Parts. Live <br />side of ground fault protection, parts of battery systems for dwellings <br />provided that there is ground fault shall be guarded to prevent acciden- <br />protection for equipment from all tal contact by persons or objects, <br />groundfault current sources. regardless of voltage or battery type. <br />(4) Equipment containing over cur- <br />rent devices in circuits supplying <br />power to a busbar or conductor <br />shall be marked to indicate the <br />presence of all sources. <br />Exception: Equipment with power <br />supplied from a single point of <br />connection. <br />(5) Equipment such as circuit <br />breakers, if backfed, shall be iden- <br />FPN: Batteries in solar photovol- <br />taic systems are subject to exten- <br />sive charge-discharge cycles and <br />typically require frequent mainte- <br />nance, such as checking electrolyte <br />and cleaning connections. <br />(C) Current Limiting. A listed, cur- <br />rent-limiting, over current device <br />shall be installed in each circuit <br />adjacent to the batteries where the <br />available short-circuit current from a <br />710-29 (Pleasanton April 2003) <br />