20.20.028 <br />692.31 Wiring Systems. <br />All raceway and cable wiring meth- <br />ods included in Chapter 3 of this <br />Code and other wiring systems and <br />fittings specifically intended and <br />identified for use with fuel cell sys- <br />tems shall be permitted. Where wir- <br />ing devices with integral enclosures <br />are used, sufficient length of cable <br />shall be provided to facilitate re- <br />placement. <br />V. Grounding <br />692.41 System Grounding. <br />For a fuel cell system output circuit, <br />one conductor of a 2-wire system <br />rated over 50 volts and a neutral <br />conductor of a 3-wire system shall be <br />solidly grounded by either 692.41(A) <br />or (B). <br />(A) Stand-Alone Systems. Grounding <br />and bonding shall be in accordance <br />with 250.30. <br />(B) Other Than Stand-Alone Sys- <br />tems. <br />(1) Two-Wire Systems. One con- <br />ductor shall be terminated at the <br />grounded circuit conductor terminal <br />of the premises wiring system. <br />(2) Three-Wire Systems. The neu- <br />tral conductor shall be terminated <br />at the grounded circuit conductor <br />terminal of the premises wiring <br />system. <br />692.44 Equipment Grounding Con- <br />ductor. <br />A separate equipment-grounding <br />conductor shall be installed. <br />692.45 Size of Equipment Grounding <br />Conductor. <br />The equipment-grounding conductor <br />shall be sized in accordance with <br />250.122. <br />692.47 Grounding Electrode System. <br />Any supplementary grounding elec- <br />trode(s) required by the manufacturer <br />shall be connected to the equipment- <br />grounding conductor specified in <br />250.118. <br />VI. Marking <br />692.53 Fuel Cell Power Sources. <br />A marking specifying the fuel cell <br />system, output voltage, output power <br />rating, and continuous output current <br />rating shall be provided at the dis- <br />connecting means for the fuel cell <br />power source at an accessible loca- <br />tion on the site. <br />692.54 Fuel Shut-Off. <br />The location of the manual fuel shut- <br />off valve shall be at the location of <br />the primary disconnecting means of <br />the building or circuits supplied. <br />692.56 Stored Energy. <br />A fuel cell system that stores elec- <br />trical energy shall require the follow- <br />ing warning sign, or equivalent, at <br />the location of the service discon- <br />necting means of the premises: <br />710-35 (Pleasanton April 2003) <br />