My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.20.028 <br />The output of a fuel cell system <br />power source shall be connected as <br />specified in 692.65(A) or (B). <br />(A) Supply Side. A fuel cell system <br />power source shall be permitted to be <br />connected to the supply side of the <br />service disconnecting means as per- <br />mitted in 230.8(5). <br />(B) Load Side. A fuel cell system <br />power source shall be permitted to be <br />connected to the load side of the ser- <br />vice disconnecting means of the <br />other source(s) at any distribution <br />equipment on the premises, provided <br />that all of the following conditions <br />are met: <br />(6) The circuit breaker on the dedi- <br />cated output of a utility interactive <br />inverter shall be positioned in the <br />distribution equipment at the oppo- <br />site (load) end from the input feed- <br />er connection or main circuit loca- <br />tion. A permanent warning label <br />shall be applied to the distribution <br />equipment with the following, or <br />equivalent: <br />WARNING <br />FUEL CELL POWER SYSTEM <br />OUTPUT. <br />DO NOT RELOCATE THIS <br />CIRCUIT BREAKER. <br />VIII. Outputs Over 600 Volts <br />(1) Each source interconnection <br />shall be made at a dedicated circuit <br />breaker or fusible disconnecting <br />means. <br />(2) The sum of the ampere ratings <br />of over current devices in circuits <br />supplying power to a busbar or <br />conductor shall not exceed the <br />rating of the busbar or conductor. <br />Exception: For a dwelling unit, the <br />sum of the ampere ratings of the <br />over current devices shall not ex- <br />ceed 120 percent of the rating of <br />the busbar or conductor. <br />(3) The interconnection point shall <br />be on the line side of all ground- <br />fault protection equipment. <br />(4) Equipment containing over cur- <br />rent devices in circuits supplying <br />power to a busbar or conductor <br />shall be marked to indicate the <br />presence of all sources. <br />(5) Equipment such as circuit <br />breakers, if back fed, shall be iden- <br />tified for such operation. <br />692.80 General. <br />Fuel cell systems with a maximum <br />output voltage over 600 volts ac <br />shall comply with the requirements <br />of other articles applicable to such <br />installations. <br />(Ord. 1869 § 5, 2002) <br />20.20.030 Article 90-4 - <br />Enforcement: <br />Section 304.2 of the Uniform Admin- <br />istrative Code Provisions for the Na- <br />tional Electrical Code, is amended as <br />follows: <br />This Chapter and the adopted Nation- <br />al Electrical Code shall be enforced <br />by the Chief Building Official acting <br />either directly or through properly <br />authorized agents acting within the <br />scope of the particular duties delegat- <br />ed to them by the Director of Public <br />Works. For such purpose the Chief <br />710-37 (Pleasanton April 2003) <br />
The URL can be used to link to this page
Your browser does not support the video tag.