My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.24.240 <br />which shall document the standards and <br />reason for the exception. <br />(2) Local Gas Shut-Off. <br />[i] Manual activation controls shall be pro- <br />vided at locations neaz the point of use and <br />near the source, as approved by the Fire <br />Chief. <br />[ii] The Fire Chief may require additional <br />controls at other places, including, but not <br />limited to, the entry to the building, the <br />area in the building where regulated materi- <br />als are stored or used, and emergency con- <br />trol stations. <br />[iii] Manually activated shut-off valves <br />shall be of "fail safe to close" design. <br />(3) Emergency Power. Emergency power <br />shall be provided for: <br />[i] Exhaust ventilation, including the power <br />supply for treatment systems. <br />[ii] Gas-detection systems. <br />[iii] Emergency building alarm systems and <br />fire detection alarm transmission to an <br />approved Underwriters Laboratory (UL) <br />Central Station Service monitoring compa- <br />ny. <br />[iv] Temperature-control systems which <br />comply with the Fire Code. <br />(4) Excess Flow Control. <br />[i] Portable tanks and cylinders shall be <br />provided with excess flow control. <br />[ii] Valves shall be permanently marked to <br />indicate the maximum design flow rate. <br />(5) Gas Detection. A continuous gas-detec- <br />tion system (in accordance with the Uni- <br />form Fire Code, Section 8003.3.1.6) shall <br />be provided to detect the presence of gas at <br />or below the permissible exposure limit. <br />The detection system shall initiate a local <br />alarm and transmit a signal to an approved <br />Underwriters Laboratory (UL) Central <br />Station Service as directed by the Fire <br />Chief, to provide an immediate response to <br />an alarm. The alarm shall be both visual <br />and' audible and shall be designed to pro- <br />vide wazning both inside and outside. of the <br />storage, use or handling area. The audible <br />alarm shall be distinct from all other on- <br />site alarms. <br />(6) Reduced Flow Valves. Reduced flow <br />valves may be utilized to reduce the maxi- <br />mum flow rate from cylinders and tanks <br />under full flow conditions. Valve flow rates <br />may be considered in determining the size <br />of treatment systems required for a worst <br />case release. <br />(7) Seismic Shut-off Valves. A seis- <br />mologically activated valve meeting stan- <br />dards approved by the Fire Chief shall be <br />provided for automatic shut off of regulated <br />materials upon a seismic event within 5 <br />seconds of horizontal semisoidal oscillation <br />having a peak acceleration of .15g <br />(=1.47m/sect) and a period of .4 seconds. <br />(8) Class II Corrosives. Inert construction <br />materials shall be used for the primary <br />containment of Class II Regulated Materi- <br />als which aze corrosives. Alternatively, <br />secondary containment shall be provided <br />for Class II materials which are corrosives. <br />(9) Emergency Alarms. When materials <br />regulated by this Article are transported <br />through exit corridors or exit enclosures, <br />there shall be an emergency telephone <br />system or a local manual alarm station or a <br />signaling device approved by the Fire Chief <br />at not more than 150-foot intervals and at <br />each exit doorway throughout the transport <br />'] 10-59 (Pleasanton April 2003) <br />
The URL can be used to link to this page
Your browser does not support the video tag.