My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.24.240 <br />single tank or cylinder of gas which pres- <br />ents the highest potential hazard. <br />[v] Systems utilized for such processing <br />shall be designed as a treatment system, as <br />described in subsection (e) 3 of this sec- <br />tion. If a total containment system is uti- <br />lized, the system shall be designed to han- <br />dle the maximum anticipated pressure of <br />release to the system when the system <br />reaches equilibrium. <br />(2) Gas Cabinets. When gas cabinets are <br />provided they shall be: <br />[ii] When more than one gas may be emit- <br />ted to the treatment system, the treatment <br />system shall be designed to handle the <br />worst case release based on the release <br />rate, the quantity and the IDLH for all the <br />gases stored or used. <br />(4) Treatment system sizing. Treatment <br />system shall be sized to process the worst <br />case release of each gas based on the maxi- <br />mum flow rate of release from the cylinder <br />or tank utilized which presents the highest <br />potential hazard. The entire contents of <br />tanks and cylinders shall be considered. <br />[i] Operated at negative pressure in relation <br />to the surrounding area. <br />[ii] Provided with self-closing limited ac- <br />cess ports or fire-rated windows to give <br />access to equipment controls. The average <br />velocity of ventilation at the face of access <br />ports or windows shall be not less than 200 <br />feet per minute (fpm) with a minimum of <br />150 fpm at any other point of the access <br />port or window. <br />[iii] Connected to a treatment system. <br />[iv] Provided with self-closing doors. <br />[v] Constructed of steel with a thickness <br />not less than 12-gauge. <br />(3) Treatment systems. <br />[i] Treatment systems shall be utilized to <br />process all exhaust ventilation to be dis- <br />charged from gas cabinets, exhausted en- <br />closures or separate storage rooms. Treat- <br />ment systems shall be designed to reduce <br />the maximum allowable discharge concen- <br />tration of the gas to one-half IDLH at the <br />point of discharge to the atmosphere as <br />specified in subsections (e)5 and 6 below. <br />(5) Stationary tanks. <br />[i] Stationary tanks shall be labeled with <br />the maximum rate of release for the gas <br />contained based on any valves or fittings <br />that are inserted directly into the tank. <br />[ii] If multiple valves or fittings are provid- <br />ed, the maximum flow rate of release for <br />the valve or fitting with the highest flow <br />rate shall be indicated. If liquefied gasses <br />are in contact with any valve or fitting, the <br />liquid flow rate shall be utilized for pur- <br />poses of computation of the maximum flow <br />rate of release. All flow rates indicated on <br />the label shall be converted to cubic feet <br />per minute of gas at normal temperature <br />and pressure. <br />(6) Portable tanks and cylinders. <br />[i] For portable tanks and cylinders, the <br />maximum flow rate of release shall be <br />calculated based on assuming the total <br />release from the cylinder or tank within the <br />time specified in the Table below: <br />Container Non liquefied Liquefied <br />Minutes Minutes <br />Cylinders 5 30 <br />Portable Tanks 40 240 <br />710-61 (Pleasanton April 2003) <br />
The URL can be used to link to this page
Your browser does not support the video tag.