My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.52.090 <br />for exterior bearing walls and ten inch- <br />es (10") for adobe partitions. No adobe <br />structure shall exceed one story in <br />height unless the historic evidence <br />satisfactory to the director of building <br />inspection and the director of planning <br />indicates a two-story height. In such <br />cases the height to thickness ratio shall <br />be the same as above for the first story <br />based on the total two-story wall <br />height, and the second floor wall thick- <br />ness shall not exceed the ratio of five <br />to one (5:1) by more than twenty per- <br />cent (20°Io). Bond beams shall be pro- <br />vided at the roof and second floor lev- <br />els. <br />2. Foundation footings shall be rein- <br />forced concrete under newly recon- <br />structed walls and shall be fifty percent <br />(50°Io) wider than the wall above, soil <br />conditions permitting, except that the <br />foundation wall may be four inches (4") <br />less in width than the wall if rock, <br />burned brick or stabilized adobe facing <br />is necessary to provide authenticity. <br />3. New or existing unstabilized brick <br />and adobe brick masonry shall test to <br />seventy five percent (75oIo) of the com- <br />pressive strength required by the uni- <br />form building code for new material. <br />Unstabilized brick may be used where <br />existing bricks are unstabilized and <br />where the building is not susceptible to <br />flooding or direct exposure to the <br />weather. Adobe may be allowed a max- <br />imum value of three (3) pounds per <br />square inch for shear with no increase <br />for lateral forces. <br />4. Mortar may be of the same soil <br />composition and stabilization as the <br />brick in lieu of cement mortar. <br />5. Nominal tension stresses due to <br />seismic forces normal to the wall may <br />be neglected if the wall meets the <br />thickness requirements and shear values <br />allowed by this subsection. <br />C. Archaic Materials: Allowable <br />stresses for archaic materials not speci- <br />fied in the state historical building code <br />shall be based on substantiating re- <br />search data or engineering judgment <br />with the approval of the director of <br />building inspection. (Ord. 1563 § 1, <br />1992) <br />(Pleasanton April 2003) 734-6 <br />