My WebLink
|
Help
|
About
|
Sign Out
2000 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2000 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:07:22 PM
Creation date
7/13/2007 3:44:40 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
4/1/2000
DOCUMENT NO
2000 APRIL
DOCUMENT NAME
SUPPLEMENT N0 9
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.08.049 <br />._._. <br />sprinklers shall be installed in ac- <br />cordance with the listing limita- <br />tions. <br />Sec. 9.406 Pipe Sizing <br />404.2 Side wall sprinklers shall be <br />positioned so that the deflectors aze <br />within 4 to 6 inches from the ceiling <br />or as listed. <br />404.3 *Sprinklers shall be posi- <br />tioned so that the response time and <br />dischazge aze not unduly affected by <br />obstructions such as ceiling slope, <br />beams, or light fixtures. See Table 3. <br />404.4 Pilot fire sprinkler protection <br />and fire detection shall be provided <br />in all attic spaces. Pilot fire sprinkler <br />locations shall be neaz heat or fire <br />sources, i.e., HVAC equipment, <br />water heaters, kitchen duct/exhaust <br />penetrations, or other electrical or <br />gas fired equipment, etc. <br />404.5 Pilot fire sprinkler sprig ups <br />or risers shall be braced in accor- <br />dance with pipe manufacturers rec- <br />ommendations for vertical support <br />and within 4 to 6 inches of the fire <br />sprinkler when the vertical riser ex- <br />ceeds 30 inches vertically. <br />Sec. 9.405 System Type <br />405.1 Wet Pipe Systems <br />A wet-pipe system shall be used <br />for all residential fire sprinkler sys- <br />tems. <br />406.1 Piping shall be sized based on <br />sprinkler(s) hydraulic demand. If <br />more than one (1) design dischazge is <br />required the pipe sizing procedure <br />shall be repeated for each design dis- <br />chazge. <br />Exception: When piping is sized <br />hydraulically, calculations shall be <br />made in accordance with the meth- <br />ods described in NFPA 13, Stan- <br />dazd for the Installation of Sprin- <br />kler Systems. Reference appropri- <br />ate friction loss tables. <br />406.2 Minimum pipe size shall be <br />3/4 inch for copper or brass, and 3/a <br />inch for plastic (CPVC). <br />406.3 *To size piping for systems <br />connected to a city water supply, the <br />hydraulically calculated or pipe size <br />method is acceptable. <br />406.3.1 Establish system flow rate <br />in accordance with Sec 9.401. <br />406.3.2 Determine water pressure <br />in the street. <br />406.3.3 Select pipe sizes. <br />406.3.4 Deduct meter pressure. <br />406.3.5 Deduct pressure loss for <br />elevation. (Building height above <br />street feet x 0.434 = psi), (Building <br />height above street in meters x 0.098 <br />- bazs). <br />'700_9 (Pleasanton April 2000) <br />