My WebLink
|
Help
|
About
|
Sign Out
2000 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2000 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:07:22 PM
Creation date
7/13/2007 3:44:40 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
4/1/2000
DOCUMENT NO
2000 APRIL
DOCUMENT NAME
SUPPLEMENT N0 9
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.08.054 <br />Where other codes, standards, or <br />specifications are referred to in this <br />specification, they are to be consid- <br />ered as only an indication of an <br />acceptable method or material that <br />can be used with the approval of <br />the building official. <br />(Ord. 1778 § 2, 1999) <br />Section 2211. Design Methods. <br />When the load combinations from <br />Section 1612.2 for LRFD are used, <br />structural steel buildings shall be <br />designed in accordance with Chapter <br />22 Division II (AISC-LRFD) and <br />Part I of AISC-Seismic as modified <br />by this Division. <br />20.08.055 Section 1900.4.4 <br />Amended -Minimum <br />Slab Thickness: <br />Section 1900.4.4 of the California <br />Building Standards Code 1998 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code, 1997 Edi- <br />tion, parts 1, 2 and 3 is amended to <br />read as follows: <br />Minimum slab thickness. The mini- <br />mum thickness of concrete floor <br />slabs supported directly on the <br />ground shall not be less than 3'/2 <br />inches (89 mm). The slab shall be <br />reinforced with not less than six <br />inches by six inches ten gauge weld- <br />ed wire mesh or an approved alter- <br />nate installed at mid height of the <br />slab. <br />(Ord. 1778 § 2, 1999; Ord. 1669 § 2, <br />1995) <br />20.08.056 Section 2211 Amended - <br />Design Methods: <br />Section 2211 of the California Build- <br />ing Standards Code 1998 Edition (24 <br />CCR), and including by reference the <br />Uniform Building Code, 1997 Edition, <br />parts 1, 2 and 3 is amended to read as <br />follows: <br />When the load combinations from <br />Section 1612.3 for ASD are used, <br />structural steel buildings shall be <br />designed in accordance with Chapter <br />22 Division III (AISC-ASD) and Part <br />III of AISC-Seismic as modified by <br />this Division. <br />(Ord. 1778 § 2, 1999) <br />20.08.057 Section 2513.1 Amended - <br />Shear-Resisting <br />Construction With <br />Wood Frame: <br />Section 2513.1 of the California <br />Building Standards Code 1998 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code, 1997 Edi- <br />tion, parts 1, 2 and 3 is amended to <br />read as follows: <br />General. Cement plaster, gypsum lath <br />and plaster, gypsum veneer base, <br />gypsum sheathing board, and gypsum <br />wallboard may be used, on wood <br />studs for vertical diaphragms if ap- <br />plied in accordance with this section. <br />Shear-resisting values shall not ex- <br />ceed those set forth in Table 25-I. <br />The effects of overturning on vertical <br />diaphragms shall be investigated in <br />accordance with Section 1605.2.2. <br />Cement plaster, gypsum lath and <br />700-21 (Pleasanton April 2000) <br />
The URL can be used to link to this page
Your browser does not support the video tag.