My WebLink
|
Help
|
About
|
Sign Out
2000 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2000 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:07:22 PM
Creation date
7/13/2007 3:44:40 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
4/1/2000
DOCUMENT NO
2000 APRIL
DOCUMENT NAME
SUPPLEMENT N0 9
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.08.059 <br />property may delete, add or modify <br />any conditions in this Chapter. <br />(Ord. 1778 § 2, 1999; Ord. 1669 § 2, <br />1995) <br />20.08.060 Section 3403.1 Amended - <br />Buildings And <br />Structures, General: <br />Section 3403.1 of the California <br />Building Standazds Code, 1998 Edition <br />(24 CCR), adopting by reference the <br />Uniform Building Code is amended to <br />read as follows: <br />General. Buildings and structures to <br />which additions, alterations or repairs <br />aze made shall comply with all the <br />requirements of this Code for new <br />facilities except as specifically pro- <br />vided in this section. See Section <br />310.9 for provisions requiring instal- <br />lation of smoke detectors in existing <br />Group R, Division 3 Occupancies. <br />When an addition or alteration af- <br />fects more than 20% of the existing <br />suspended ceiling system, then the <br />entire ceiling system within the im- <br />provement azea is to be designed for <br />lateral design requirements of the <br />California Building Standazds Code <br />1998 Edition (24 CCR), adopting by <br />reference the Uniform Building Stan- <br />dazd 25-2 Part III. <br />(Ord. 1778 § 2, 1999; Ord. 1669 § 2, <br />1995) <br />20.08.062 Section 1804.1 Amended - <br />General: <br />Section 1804.1 of the California <br />Building Standazds Code 1998 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code, 1997 Edi- <br />tion, parts 1, 2 and 3 is amended to <br />read as follows: <br />1804.1 General. A civil engineer or <br />geotechnical engineer licensed in <br />California shall determine the classi- <br />fication of the soil for all building <br />sites. <br />EXCEPTION: <br />1. Group U occupancies <br />2. Additions to existing Group R3 <br />occupancies when total added floor <br />azea is less than 50% of existing <br />floor azea and the slope of the lot <br />does not exceed 15% <br />3. Accessories and minor additions <br />may be exempted by the building <br />official. <br />(Ord. 1778 § 2, 1999) <br />20.08.064 Section 1804.2 Amended - <br />General: <br />Section 1804.2 of the California <br />Building Standazds Code 1998 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code, 1997 Edi- <br />tion, parts 1, 2 and 3 is amended to <br />read as follows: <br />1804.2 Investigation. The investiga- <br />tion shall be based on observation <br />and tests of the materials disclosed <br />by borings or excavations made in <br />appropriate locations. Additional <br />studies may be necessary to evaluate <br />soil strength, the effect of moisture <br />(Pleasanton April 2000) '702 <br />
The URL can be used to link to this page
Your browser does not support the video tag.