1. Fire walls (area separation walls) shall not be used to divide a large building into <br />sections of 4 units or less in order to reduce the number of units in order to qualify for <br />use of these criteria. <br />2. Fire sprinklers shall be located in residential areas per NFPA 13D. The number of <br />design sprinklers shall include all sprinklers within a compartment to a maximum of 3 <br />sprinklers. The flow rate, k factor, and temperature rating shall be per the sprinklers <br />manufacturers listing for the area covered. When the number of sprinklers in a <br />compartment is less than 3, the calculations shall include a 5 gallon per minute <br />domestic use simultaneous with the design sprinkler flow. The domestic demand shall <br />be added at the base of the riser. <br />3. Fire sprinklers shall be provided in the attic. Fire sprinklers shall be spaced a <br />maximum of 30' on center below the roof peaks (and a maximum of 15' from the wall <br />for gable roofs) and over all furnaces, water heaters, etc. All attic areas over 100 <br />square feet shall be covered (some houses have several attic areas). Attics with flat <br />roofs shall have sprinklers spaced a maximum of 30' on center and a maximum of 15' <br />from the walls. Attic sprinklers shall be 200° - 212° (degree) F, quick response or <br />standard response, 7/16" orifice (K=4.0 to 4.5). <br />4. Fire sprinklers shall be provided between floors where floor ceiling assemblies <br />consist of open web joists or trusses. Sprinklers shall be spaced a maximum of 30' on <br />center and a maximum of 15' from walls. Sprinklers shall be 200° - 212° (degree) F, <br />quick response or standard response, 7/16" orifice (K=4.0 to 4.5). <br />5. Fire sprinklers shall be provided in the garage. Fire sprinklers in garages shall be <br />200° (degree) F, quick response type, 7/16" orifice (K = 4.0 to 4.5) with a maximum <br />spacing of 140-150 square feet per sprinkler. <br />6. Pipe type. UL approved plastic pipe shall be protected per the listing except that <br />piping to the fire sprinklers in the attic and pipe in the concealed spaces between floors <br />may be exposed within the space. <br />This guideline does not apply to motels, hotels, or day care centers with more than 12 <br />occupants. These types of buildings shall have fire sprinklers designed and installed <br />per NFPA 13. <br />Chapter 4-General Requirements -amended <br />Section 4.3.1 is amended to read: <br />Section 4.3.1 All systems shall be tested for leakage at 200 psi for two (2) hours <br />minimum. Exception: Minor additions to an existing house may be tested at street <br />pressure. Where additional pressure testing is needed for existing systems the <br />pressure shall be 50 psi over street pressure for a minimum of 2 hours. <br />Chapter 5-System Components -added <br />Section 5.2.1.4 is added to read: <br />Section 5.2.1.4 All sprinkler riser piping shall be either non-ferrous metallic pipe <br />(copper, or brass) or CPVC. All piping above the flow switch shall be protected by sheet <br />ss <br />
The URL can be used to link to this page
Your browser does not support the video tag.