for liquid hazardous materials and for highly toxic and toxic corrosive gases above <br />threshold quantities listed in Tables 3704.2 and 3704.3. Secondary containment <br />includes, but is not limited to double walled piping. <br />EXCEPTIONS: <br />1. Secondary containment is not required for toxic corrosive gases if the piping is <br />constructed of inert materials. <br />2. Piping under sub-atmospheric conditions if the piping is equipped with an alarm and <br />fail-safe-to-close valve activated by a loss of vacuum. <br />3. Expansion chambers shall be provided between valves whenever the regulated gas <br />may be subjected to thermal expansion. Chambers shall be sized to provide protection <br />for piping and instrumentation and to accommodate the expansion of regulated <br />materials. <br />Amend Section 2703.2.2.2 to read: <br />2703.2.2.2 Additional Regulation for Supply Piping for Health Hazard Materials. Supply <br />piping and tubing for gases and liquids having a health hazard ranking of 3 or 4 in <br />accordance with ASME 631.3 and the following: <br />1. Piping and tubing utilized for the transmission of toxic, highly toxic, or highly volatile <br />corrosive liquids and gases shall have welded brazed connections throughout except <br />for connections within an exhausted enclosure if the material is a gas, or an approved <br />method of drainage or containment is provided for connections if the material is a liquid. <br />2. Piping and tubing shall not be located within corridors, within any portion of a means <br />of egress required to be enclosed in fire-resistance-rated construction or in concealed <br />spaces in areas not classified as Group H Occupancies. <br />EXCEPTION: <br />Piping and tubing within the space defined by the walls of corridors and the floor or roof <br />above or in concealed space above other occupancies when installed in accordance <br />with Section 415.8.6.3 of the California Building Code as required for Group H, Division <br />5 Occupancies. All primary piping for toxic, highly toxic and moderately toxic gases <br />shall pass a helium leak test of 1x10-9 cubic centimeters/second where practical, or <br />shall pass testing in accordance with an approved, nationally recognized standard. <br />Tests shall be conducted by a qualified "third party" not involved with the construction of <br />the piping and control systems. <br />Amend Section 2703.3.1 as follows: <br />2703.3.1 Unauthorized Discharges. When hazardous materials are released in <br />quantities reportable under state, federal or local regulations or when there is release or <br />a threatened release that presents a threat to health, property or the environment, the <br />fire code official shall be notified immediately in an approved manner and the following <br />procedures required in accordance with Sections 2703.3.1.1 through 2703.3.1.4. <br />Add Section 2703.5.3 to read: <br />94 <br />
The URL can be used to link to this page
Your browser does not support the video tag.