Laserfiche WebLink
20.24.060 CFC Chapter 6 amended -Building Services and Systems. <br />CFC Section 605.11 is added: <br />605.11 Immersion Heaters. All electrical immersion heaters used in dip tanks, sinks, <br />vats and similar operations shall be provided with approved over-temperature controls <br />and low liquid level electrical disconnects. Manual reset of required protection devices <br />shall be provided. <br />20.24.070 CFC Chapter 6 added -Building Services and Systems. <br />CFC Section 608.6.3 is added: <br />608.6.3 Failure of Ventilation System. Failure of the ventilation system shall <br />automatically disengage the charging system. <br />20.24.080 CFC Section 903.2 amended -Fire Extinguishing Systems-Where required. <br />CFC Section 903.2 is amended: <br />903.2 An automatic fire extinguishing system or other approved fire suppression <br />system(s) shall be installed as follows: <br />1. In every building where the floor and basement area exceeds 8000 square feet. <br />Exceptions: <br />1. Group U, Division 1 private garages of 1,000 square feet or less. <br />2. Group U, Division 2 Occupancies. <br />2. In all buildings of all occupancies except Groups R1, R3 and U occupancies on a <br />parcel when the building(s) area(s) on the parcel exceeds 8,000 square feet of floor <br />area, including area of basements. <br />3. All buildings residential or commercial over 5 minutes response time, as determined <br />by the Fire chief, from a City fire station. <br />4. Any structure in any area or location determined by the Fire Chief to be a high fire <br />hazard. High fire hazard area shall be defined as those areas beyond five minutes <br />driving time of fire apparatus from the fire station serving those particular districts; or <br />areas determined by the Fire Chief to be either high hazard areas or extreme hazard <br />areas based on steepness of slope and/or fuel loadings from combustible plant <br />materials as set forth in the Safety Element of the General Plan. <br />5. In every story or basement of all buildings when the floor area exceeds 1,500 <br />square feet (139.4 m2) and there is not provided at least 20 square feet (1.86 m2) of <br />opening entirely above the adjoining ground level in each 50 lineal feet (15 240 mm) or <br />fraction thereof of exterior wall in the story or basement on at least one side of the <br />building. Openings shall have a minimum dimension of not less than 30 inches (762 <br />mm). Such openings shall be accessible to the fire department from the exterior and <br />shall not be obstructed in a manner that firefighting or rescue cannot be accomplished <br />from the exterior. When openings in a story are provided on only one side and the <br />83 <br />