My WebLink
|
Help
|
About
|
Sign Out
ORD 1965
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1901 - 2000
>
ORD 1965
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:23:47 PM
Creation date
1/9/2008 11:34:53 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 1965
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
available, the container shall be used with aflow-limiting device. All flow limiting devices <br />shall be part of the valve assembly and visible to the eye when possible; otherwise, <br />they shall be installed as close as possible to the cylinder source. <br />Add Section 3704.1.8 to read: <br />3704.1.8 Annual Maintenance. All safety control systems at a facility shall be <br />maintained in good working condition and tested not less frequently than annually. <br />Maintenance and testing shall be performed by persons qualified to perform the <br />maintenance and tests. Maintenance records and certifications shall be available to any <br />representative of the Livermore Pleasanton Fire Department for inspection upon <br />request. <br />Add Section 3704.1.9 to read: <br />3704.1.9 Fire Extinguishing Systems. Buildings and covered exterior areas for storage <br />and use areas of materials regulated by this Chapter shall be protected by an automatic <br />fire sprinkler system in accordance with NFPA 13. The design of the sprinkler system <br />for any room or area where highly toxic, toxic and moderately toxic gases are stored, <br />handled or used shall be in accordance with Section 2704.5. <br />Add Section 3704.1.10 to read: <br />3704.1.10 Local Gas Shut Off. Manual activation controls shall be provided at locations <br />near the point of use and near the source, as approved by the fire code official. The <br />fire code official may require additional controls at other places, including, but not <br />limited to, the entry to the building, storage or use areas, and emergency control <br />stations. <br />Manual activated shut-off valves shall be of afail-safe-to-close design." <br />Add Section 3704.1.11 to read: <br />3704.1.11 Exhaust Ventilation Monitoring. For highly toxic gases and toxic gases <br />exceeding threshold quantities, a continuous monitoring system shall be provided to <br />assure that the required exhaust ventilation rate is maintained. The monitoring system <br />shall initiate a local alarm. The alarm shall be both visual and audible and shall be <br />designed to provide warning both inside and outside of the interior storage, use, or <br />handling area. <br />Add Section 3704.1.12 to read: <br />3704.1.12 Emergency Response Plan. If the preparation of an emergency response <br />plan for the facility is not required by any other law, responsible persons shall prepare, <br />or cause to be prepared, and filed with the fire code official, a written emergency <br />response plan. If the preparation of an emergency response plan is required by other <br />law, a responsible person shall file a copy of the plan with the Fire Chief. <br />Add Section 3704.1.13 to read: <br />3704.1.13 Emergency Response Team. Responsible persons shall be designated and <br />trained to be liaison personnel for the Livermore Pleasanton Fire Department. These <br />persons shall aid the Fire Department in preplanning emergency responses, identifying <br />98 <br />
The URL can be used to link to this page
Your browser does not support the video tag.