My WebLink
|
Help
|
About
|
Sign Out
09 ATTACHMENTS
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2009
>
021709
>
09 ATTACHMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2009 1:21:44 PM
Creation date
2/12/2009 4:35:29 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
2/17/2009
DESTRUCT DATE
15 Y
DOCUMENT NO
09 ATTACHMENTS
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CORNERSTONE <br />EARTH GROUP <br />9.2 PORTLAND CEMENT CONCRETE <br />The exterior Portland Cement Concrete (PCC) pavement recommendations tabulated below are <br />based on methods presented in the PCA design manual (need reference). Recommendations <br />for garage slabs-on-grade were provided in the "Concrete Slabs and Pedestrian Pavements" <br />section above. We have provided a few pavement alternatives as an anticipated Average Daily <br />Truck Traffic (ADTT) was not provided. An allowable ADTT should be chosen that is greater <br />than what is expected for the development. <br />Table 8: PCC Pavement Recommendations (R-value = 70) <br /> <br />Allowable ADTT Minimum PCC <br />Thickness <br />(inches) <br />0.8 5 <br />13 5.5 <br />130 6 <br />The PCC thicknesses above are based on a concrete compressive strength of at least 3,500 <br />psi, supporting the PCC on at least 4 inches of Class 2 aggregate base compacted as <br />C recommended in the "Earthwork" section, and laterally restraining the PCC with curbs or <br />concrete shoulders. Adequate expansion and control joints should be included. Consideration <br />should be given to limiting the control joint spacing to a maximum of about 2 feet in each <br />direction for each inch of concrete thickness. <br />9.3 VEHICULAR CONCRETE UNIT PAVERS <br />Where vehicular concrete unit pavers are desired in standard traffic areas, we recommend that <br />the pavers be underlain by a 6-inch-thick concrete sub-slab designed as discussed above, <br />including the aggregate base section. Pavers should be placed on a bituminous or mortar <br />setting bed over the concrete sub-slab. Where the pavers will be used as an emergency vehicle <br />access (EVA), the pavers should be placed over at least 12 inches of Class 2 aggregate base <br />and prepared subgrade as recommended in the "Earthwork" section. A maximum 1 inch thick <br />sand setting bed may be used to level the pavers on the aggregate base. <br />9.4 PAVEMENT CUTOFF <br />Surface water penetration into the pavement section can significantly reduce the pavement life, <br />due to the native expansive clays. While quantifying the life reduction is difficult, a normal 20- <br />year pavement design could be reduce to less than 10 years; therefore, increased long-term <br />maintenance may be required. A curb subdrain should be incorporated into the design of the <br />street sections in accordance with the City of Pleasanton Public Works Department Curb <br />subdrain, Detail No. 209. <br />Ponderosa Active Adult Community Page 22 <br />132-2-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.