SUPPLEMENTAL MATERIAL <br />1 <br />Responses to City Council Agenda Items – June 2, 2026 <br />Regular Meeting <br />Agenda Item #11: Approve the proposed Sewer Rate Structure, Sewer Rate, and <br />updated Sewer Connection Fees to support implementation of the Sewer Rate Study's <br />Financial Plan Scenario 1 - Maintain <br />1.Last November, the projected failure rate of the system was based on closed- <br />circuit television (CCTV) inspections. At that time, only about 30% of the system <br />had been inspected by CCTV, so the condition of the remaining 70% of the <br />system was an estimate. I’m assuming CCTV inspections are continuing, has the <br />failure or condition rate changed since those additional inspections? <br />(Note this was meeting held on 11/4 and was an item continued from 10/21). <br />A.Since November, Public Works has continued its annual sewer cleaning and <br />CCTV inspection program, which targets approximately 190,000 linear feet of <br />sewer main each year. This ongoing effort allows the City to complete a full <br />inspection cycle of the sewer collection system approximately every seven <br />years. <br />As additional CCTV inspections have been completed, staff has gathered <br />more detailed condition information on the sewer system. Based on the <br />inspections performed to date, there has not been a significant change in the <br />overall projected condition or failure rate of the system compared to what was <br />presented in November. As a result, the assumptions used in the sewer rate <br />study and the recommended Maintain Scenario remain valid. <br />While the overall system condition has remained generally consistent with <br />previous projections, the additional inspections have enabled staff to better <br />identify and prioritize specific locations requiring rehabilitation or replacement. <br />For example, recent CCTV inspections identified additional deteriorated <br />sewer main segments along Denker Road that warrant replacement. To <br />address this deficiency and reduce the risk of future failures, approximately <br />$1.09 million has been included in the FY 2026/27 Capital I mprovement <br />Program for sewer main replacement in this area. <br />Staff will continue to perform CCTV inspections and condition assessments to <br />refine project priorities, improve asset management planning, and ensure that <br />capital investments are focused on the highest-risk portions of the system.