My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
[ii] Expansion chambers may be provided between valves whenever the regulated gas <br />may be subjected to thermal expansion. Chambers shall be sized to provide protection <br />for piping, valves and instrumentation and to accommodate the expansion of regulated <br />materials. <br /> <br />(2) Signage. <br /> <br />[i] Stationary above ground tanks shall be placarded with hazard identification signs as <br />specified in Fire Code Standard No.79-3, for the specific material contained. <br /> <br />[ii] Signs prohibiting smoking shall be posted in indoor storage, use and handling areas <br />and within 25 feet of outdoor storage, use and handling areas. <br /> <br />[iii] Signs shall not be obscured or removed. <br /> <br />[iv] Signs shall be in English and such other languages as may be appropriate, as <br />determined by the Fire Chief. <br /> <br />[v] Signs shall be durable. <br /> <br />[vi] The size, color and lettering shall be in conformance with nationally recognized <br />standards determined by the Fire Chief to be applicable to the regulated material, (i.e. <br />NFPA 704 System). <br /> <br />(3) Inert Gas Purge System. Gas systems for regulated materials shall be provided with <br />individually dedicated inert gas purge systems (e.g., nitrogen, helium, argon and neon). <br /> <br />(e) Minimum Threshold Quantity Controls. Responsible persons shall cause <br />materials which do not exceed the Minimum Threshold Quantity to be provided with the <br />controls specified in this subsection (e) and in subsection (f) of this section. <br /> <br />(1) Exhaust Ventilation. <br /> <br />[i] Storage of cylinders shall be within ventilated gas cabinets, exhausted enclosures or <br />within a ventilated separate gas storage room as defined in the Fire Code. <br /> <br />[ii] Storage of portable and stationary tanks shall be within a separate ventilated room <br />without other occupancy or use. <br /> <br />[iii] If gas cabinets are provided, the room or area in which they are located shall have <br />independent exhaust ventilation. <br />[iv] Exhaust systems for gas cabinets, exhausted enclosures and separate gas storage <br />rooms shall be designed to handle the accidental release of gas. Such exhaust systems <br /> 122 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.