connection Control and Hydraulic Research (FCCC & <br />H R) of the University of Southern California established <br />by: <br />Specifications of Backflow Prevention De- <br />vices 669 -2 dated March 1969 or the most current <br />issue. <br />Said AWWA and FCCC & HR standards and <br />specifications have been adopted by the operations ser- <br />vices director. Final approval shall be evidenced by a <br />certificate of approval issued by an approved testing <br />laboratory certifying full compliance with said AWWA <br />standards and FCCC & HR specifications. The follow- <br />ing testing laboratory has been qualified by the opera- <br />tions services director to test and certify backflow pre - <br />venters: <br />Foundation for Cross- connection <br />Control and Hydraulic Research <br />University of Southern California <br />University Park <br />Los Angeles, California 90007 <br />Testing laboratories other than the laboratory <br />listed above will be added to an approved list as they are <br />qualified by the operations services director. <br />Backflow preventers which may be subjected to <br />back pressure or back- siphonage that have been fully <br />tested and have been granted a certificate of approval by <br />the qualified laboratory and are listed on the laboratory's <br />current list of approved devices may be used without <br />further test or qualification. <br />F. It shall be the duty of the customer -user at <br />any premises where backflow prevention devices are <br />installed to have certified inspections and operational <br />tests and repairs made at least once per year. In those <br />instances where the operations services director deems <br />the hazard to he great enough, he or she may require <br />certified inspections at more frequent intervals. These <br />inspections, tests and repairs shall be at the expense of <br />the water user and shall he performed by the device <br />manufacturer's representative, or by a certified tester <br />approved by the operations services director. 11 shall be <br />the duty of the operations services director to see that <br />these timely tests are made. The customer -user shall <br />notify the operations services director in advance when <br />the tests are to be undertaken so that he or she or his or <br />her representative may witness the tests if so desired. <br />These devices shall be repaired, overhauled or replaced <br />by a certified individual or agency at the expense of the <br />customer -user whenever the devices are found to be <br />389 <br />14.16.050 <br />defective. Records of such tests, repairs and overhaul <br />shall be kept and made available to the operations ser- <br />vices director. <br />G. All presently installed backflow devices <br />which do not meet the requirements of this section but <br />were approved devices for the purposes described herein <br />at the time of installation and which have been properly <br />maintained, shall, except for the inspection and mainte- <br />nance requirements under subsection F of this section, <br />be excluded from the requirements of these rules so long <br />as the operations services director is assured that they <br />will satisfactorily protect the utility system. Whenever <br />the existing device is moved from the present location or <br />requires more than minimum maintenance or when the <br />operations services director finds that the maintenance <br />constitutes a hazard to health, the unit shall be replaced <br />by a backflow prevention device meeting the require- <br />ments of this section. <br />H. All existing water connections which may <br />be deemed by the operations services director to be sub- <br />ject to backflow prevention will, upon written notice, <br />have an appropriate backflow prevention device in- <br />stalled and inspected within 60 days of the notification. <br />(Ord. 2000 § I, 2009; Ord. 1073 § 3 (part), 1983: prior <br />code § 2 -16.50 (2)) <br />(Pleasanton Supp. No. 3, I -LLn <br />