Laserfiche WebLink
14.16.050 <br />When such a condition becomes known, the operations <br />services director shall deny or immediately discontinue <br />service to the premises by providing for a physical break <br />in the service line until the customer has corrected the <br />conditions in conformance with state and city statutes <br />relating to plumbing and water supplies and the regula- <br />tions adopted pursuant thereto. <br />C. An approved backflow prevention device <br />shall also be installed on each service line to a cus- <br />tomer's water system in all cases, before the first branch <br />line leading off the service line wherever the following <br />conditions exist: <br />I. In the case of premises having an auxiliary <br />water supply which is not or may not be of safe bacterio- <br />logical or chemical quality and which is not acceptable <br />as an additional source by the operations services direc- <br />tor, the public water system shall be protected against <br />backflow from the premises by installing a backflow <br />prevention device in the service line appropriate to the <br />degree of hazard. <br />2. In the case of premises on which any indus- <br />trial fluids or any other objectionable substance is han- <br />dled in such a fashion as to create an actual or potential <br />hazard to the public water system, the public system <br />shall be protected against backflow from the premises <br />by installing a backflow prevention device in the service <br />line appropriate to the degree of hazard. This shall in- <br />clude the handling of processed waters and waters origi- <br />nating from the utility system which have been subject <br />to deterioration in quality. <br />3. In the case of premises having (a) internal <br />cross- connections that cannot be permanently corrected <br />and controlled, or (b) intricate plumbing and piping ar- <br />rangements or where entry to all portions of the prem- <br />ises is not readily accessible for inspection purposes, <br />making it impracticable or impossible to ascertain <br />whether or not dangerous cross - connections exist, the <br />public water system shall be protected against backflow <br />from the premises by installing a backflow prevention <br />device in the service line. <br />D. The type of protective device required under <br />subsections (C)(1), (2) and (3) of this section shall de- <br />pend upon the degree of hazard which exists as follows: <br />1. In the case of any premises where there is an <br />auxiliary water supply as stated in subsection (C)(I) of <br />this section and it is not subject to any of the following <br />rules, the public water system shall be protected by an <br />approved air -gap separation or an approved reduced <br />pressure principle backflow prevention device. <br />2. In the case of any premises where there is <br />water or substance that would be objectionable but not <br />hazardous to health, if introduced into the public water <br />(Pleasanlon Snpp. No 3, 1 -10) <br />388 <br />system, the public water system shall be protected by an <br />approved double check valve assembly. <br />3. In the case of any premises where there is <br />any material dangerous to health which is handled in <br />such a fashion as to create an actual or potential hazard <br />to the public water system, the public water system shall <br />be protected by an approved air -gap separation or an <br />approved reduced pressure principle backflow preven- <br />tion device. Examples of premises where these condi- <br />tions will exist include chemical manufacturing plants, <br />hospitals, mortuaries and plating plants. <br />4. In the case of any premises where there are <br />"uncontrolled" cross - connections, either actual or poten- <br />tial, the public water system shall be protected by an <br />approved air -gap separation or an approved reduced <br />pressure principle backflow prevention device at the <br />service connection. <br />5. In the case of any premises where, because <br />of security requirements or other prohibitions or restric- <br />tions it is impossible or impractical to make a complete <br />in -plant cross - connection survey, the public water sys- <br />tem shall be protected against backflow or back - <br />siphonage from the premises by the installation of a <br />backflow prevention device in the service line. In this <br />case, maximum protection will be required; that is, an <br />approved air -gap separation or an approved reduced <br />pressure principle backflow prevention device shall be <br />installed in each service to the premises. <br />6. In the case of premises with cross - <br />connections to sewage lines, pumps, flushers, etc., the <br />public water system shall be protected by an approved <br />air -gap separation or an approved reduced pressure prin- <br />ciple backflow prevention device. Examples include <br />sewage treatment plants and pumping stations. <br />7. In the case of tanker and spray tanks of <br />forty -nine gallons or more, air -gap separation or an ap- <br />proved reduced pressure principle backflow prevention <br />device is required. <br />E. Any backflow prevention device required in <br />this chapter shall be of a model and size approved by the <br />operations services director. The term "approved back- <br />flow prevention device" means a device that has been <br />manufactured in full conformance with the standards <br />established by the American Water Works Association <br />(AWWA) entitled: <br />AWWA C506 -78 Standards for Reduced <br />Pressure Principle and Double Check Valve Back - <br />flow Prevention Devices: <br />and, have met completely the laboratory and field <br />performance specifications of the Foundation for Cross- <br />