My WebLink
|
Help
|
About
|
Sign Out
11 ATTACHMENT 04
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2011
>
090611
>
11 ATTACHMENT 04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/26/2011 4:25:48 PM
Creation date
8/26/2011 2:55:00 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
9/6/2011
DESTRUCT DATE
15Y
DOCUMENT NO
11 ATTACHMENT 04
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- 15 - <br /> Traffic and rail noise diminish at a rate of 3-6 dB for each doubling of the distance <br /> from the source to the receiver. Thus. other locations on the site at greater distances from <br /> the roadways or railroad will have lower noise levels. Additional acoustical shielding <br /> will be provided by interposed buildings of the project. <br /> B. Future Noise Levels <br /> Future traffic volume data for Stanley Boulevard were acquired from information <br /> contained the City of Pleasanton Noise Element. The Noise Element provides traffic <br /> volume data for many roadways throughout the City for year 2008 (time of the General <br /> Plan) and for future year 2025. The traffic volume for Stanley Bottles and is predicted to <br /> increase from the existing 7.800 ADT to 14,000 ADT for 2025. This increase in traffic <br /> volume yields a 3 dB increase in the traffic noise levels. <br /> C. Ground-Borne Vibration <br /> To determine the levels of railroad induced ground vibration. vibration level <br /> measurements were made at a location 70 ft. from the centerline of the railroad tracks. <br /> The measurements were made on March 13. 2009 using a PCB Piezotronics 393A03 <br /> accelerometer and a Larson Davis 2900 Dual Channel Real Time analyzer. The analyzer <br /> measured real time I%3-octave band vibration levels. in dB re: 1 x 10`' in./sec. for the <br /> three orthogonal directions over the frequency range of 0.8 to ]0 kHz. The vibration <br /> levels from 8 Hz to 80 Hz were used to assess the impact of ground borne vibration on <br /> homes of the project. Table IV on the following page provides the measured vibration <br /> levels for each type of train operation. <br /> TABLE IV <br /> Measured Ground Vibration Levels, VdB <br /> Freq.(Hz) 8 10 12.5 16 20 25 315 40 50 63 80 tOtAl. <br /> I i <br /> Freight 44.2 51.0 4 52.1 49.1 56.7 64.0 68.7 72.4 72.6 66.4 64.6 77.3 <br /> ACE 31.4 31 .7 38.4 42.5 47.4 52.9 61.7 67.1 66.6 57.0 51.4 70.8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.