Laserfiche WebLink
, <br /> enclosures or capacity banks can be installed above ground provided the units are <br /> screened with landscaping to the satisfaction of the Director of Community Development <br /> 142 Prior to requesting for an acceptance of the subdivision improvements the project applicant <br /> shall provide <br /> a The project AS BUILT plans (grading plans, improvement plans, joint trench plans, <br /> street lighting plans) in PDF format for City record <br /> b The project base sheet showing all utilities in AutoCAD 2010 version for City GIS <br /> Department <br /> c The project final soils report signed by the Geotechnical Engineer in PDF format <br /> d The project Mass Grading Plans, in PDF format, signed by the Geotechnical <br /> Engineer two times <br /> i First time, signed before construction, for approval of the Mass Grading and <br /> Improvement plans for compliance with the Geotechnical Report and <br /> ii Second time, signed after construction certifying that all grading, site preparation, <br /> placing and compaction of fill was done in accordance with the Geotechnical <br /> recommendations <br /> Livermore-Pleasanton Fore Department <br /> 143 The project applicant shall keep the site free of fire hazards from the start of lumber <br /> construction until the final inspection <br /> 144 Prior to any construction framing, the project applicant shall provide adequate fire <br /> protection facilities, including, but not limited to a water supply and water flow in <br /> conformance to the City's Fire Department Standards able to suppress a major fire <br /> 145 All curbs located with a seven-foot, six-inch radius of a public/private fire hydrant shall be <br /> painted red, unless, modified by the Fire Chief Blue street "hydrant markers" shall be <br /> installed for all fire hydrants per City of Pleasanton Standard Specifications <br /> 146 All private streets and driveway aisles designated as fire lanes by the Fire Chief shall be <br /> maintained in accordance with the California Fire Code which permits towing vehicles <br /> illegally parked on the fire lanes Fire lane curbs shall be painted red with "No Parking, <br /> Fire Lane, Tow Away Zone" or "No Parking, Fire Lane, Tow Away Zone" signs shall be <br /> installed as required by the Vehicle Code <br /> 147 All fire sprinkler system water flow and control valves shall be complete and serviceable <br /> prior to final inspection <br /> 148 The following items will be provided prior to any construction above the foundation or slab <br /> NOTE Periodic inspections will be made for compliance <br /> a Emergency vehicle access shall be provided to the site, including the area where <br /> construction is occurring If Public Works improvements are part of the project to <br /> PUD-110, Irby Ranch City Council <br /> Page 24 of 31 <br />