Laserfiche WebLink
Page 2 PUD-105 and P14-0852 <br /> July 9, 2019 <br /> JDEDZ <br /> Health Risk Assessment <br /> The HRA evaluates potential health risks associated with toxic air contaminants(TACs)resulting from the <br /> JDEDZ. Health risks were assessed for exposure of nearby sensitive receptors to TAC emissions resulting from <br /> construction and operation of the JDEDZ. The HRA was conducted to evaluate whether construction and <br /> operation of the JDEDZ would expose sensitive receptors to substantial concentrations of TACs or respirable <br /> particulate matter,and whether JDEDZ project-level impacts related to TAC exposure would be significant. The <br /> HRA was also prepared to assess the exposure of sensitive receptors to cumulative concentrations of TACs and <br /> respirable particulate matter from construction and operation of the JDEDZ when combined with past, present <br /> and other reasonably foreseeable development in the vicinity, including existing permitted stationary sources <br /> and Interstates 680 and 580. <br /> The HRA evaluates JDEDZ risks at existing on-site businesses and surrounding residential units, businesses and <br /> fitness clubs that are within 1,000 feet of the JDEDZ boundary. Both sensitive receptors and worker receptors <br /> within the study domain were included. Although the Bay Area Air Quality Management District(BAAQMD) <br /> does not consider worker receptors as sensitive receptors, and therefore does not require that HRAs include <br /> worker risk evaluation,the HRA includes worker risk for existing off-site and existing on-site worker exposures <br /> to provide a comprehensive and conservative assessment of potential risk associated with the JDEDZ. <br /> The maximum potential lifetime excess cancer risk associated with the JDEDZ is 5.4 in a million (occurs at <br /> an off-site residential receptor location), which would not exceed the BAAQMD cancer risk threshold of 10 <br /> in a million. The maximum potential chronic health risk associated with the JDEDZ is 0.52(occurs at an off- <br /> site worker receptor location), which would not exceed the BAAQMD's hazard index threshold of 1. The <br /> maximum potential annual average PM2.5 concentration associated with the JDEDZ is 0.22 micrograms per <br /> cubic meter(pg/n?) (occurs at an off-site worker receptor location), which would not exceed the BAAQMD's <br /> threshold of 0.3 pg/m3. Therefore,JDEDZ project-level impacts due to exposure of TACs to sensitive <br /> receptors would be less than significant. <br /> The maximum potential cumulative lifetime excess cancer risk associated with the JDEDZ and all <br /> background TAC sources within 1,000 feet of the project is 86.5 in a million (occurs at an off-site worker <br /> receptor location), which would not exceed the BAAQMD cumulative cancer risk threshold of 100 in a <br /> million. The maximum potential cumulative chronic health risk associated with the JDEDZ is 0.64(occurs at <br /> an off-site worker receptor location), which would not exceed the BAAQMD's hazard index threshold of 10. <br /> The maximum potential cumulative annual average PM2.5 concentration associated with the JDEDZ is 0.59 <br /> ,ug/m3(occurs at an off-site worker receptor location), which would not exceed the BAAQMD's threshold of <br /> 0.8 pg/m3. Therefore,cumulative impacts due to exposure of TACs to sensitive receptors would be less than <br /> significant. <br /> Updated Air Quality Technical Memorandum- Criteria Pollutant Emissions Analysis <br /> The technical memorandum presents the updated criteria pollutant emissions analysis for Section 4.B—Air <br /> Quality of the SEIR for the JDEDZ. As noted above,a HRA has been prepared and is also being added to the <br /> SEIR.Consistent with new modeling data used for the HRA,this technical memorandum supplements Section <br /> 4.B of the Draft SEIR with an updated analysis of criteria pollutants emissions including reactive organic carbon <br /> (ROG), nitrogen oxides(NOx),construction related exhaust particulate matter(PM), particulate matter with an <br /> aerodynamic diameter equal to or less than 10 microns(PM10),particulate matter with an aerodynamic diameter <br /> equal to or less than 2.5 microns(PM25),and carbon monoxide(CO). <br /> COMMUNITY DEVELOPMENT— P. O. BOX 520, Pleasanton, CA 94566-0802 <br /> Planning Building&Safety Engineering Traffic Inspection <br /> 200 Old Bernal Ave. 200 Old Bernal Ave. 200 Old Bernal Ave. 200 Old Bernal Ave. 157 Main St. <br /> (925)931-5600 (925)931-5300 (925)931-5650 (925)931-5650 (925)931-5680 <br /> Fax: 931-5483 Fax: 931-5478 Fax: 931-5479 Fax: 931-5479 Fax: 931-5484 <br />